Ecofit M29-A3 VGCUG9 200V 120-volt, 1-phase, 50-60 Hz. Ecofit EC tube axial fan (motorized impeller), includes: 150 watts / 3515 rpm max, UL-R & IP44 motor Class F, with separate power & control connection cables (380-mm from the fan housing), operating temperature -25° to +60° celsius, speed control, 200-mm diameter polyamide (PA 6/6, UL94 V0) impeller; square aluminum housing with two mounting flanges dimensions 218 x 218.
Ecofit M36-A6 GREUG9 160x62R; 120V, 1-phase, 50-60 Hz. Ecofit EC single inlet forward curved blower (motorized impeller), standard airflow /pressure output, includes: IP44 & UL-R EC motor Class F, nominal 142 watts & 1910 rpm, with soft start, speed controlable, 900-mm separate power & control connection cables, operating temperature -25°c to +60°c at full speed; impeller made of galvanized steel; scroll housing made of painted or galvanized steel.
Ecofit U24-D4 RREUG9 220 x 43R; 230V, 1-phase, 50-60 Hz. Ecofit EC backward curved motorized impeller, includes: IP44 and UL-R motor Class F, nominal 150 watts / 3395 rpm max, operating temperature -20°C to +50°C, 900-mm connection wires (power input three wires, speed control three wires, tachometer output two wires); very high efficiency impeller made of PPC-T20 polypropylene.
Ecofit R27-A0 GDSUV8 180x180l constant airflow; 200-277-volt, 1-phase, 50-60 Hz input voltage; Ecofit EC double inlet forward curved blower (motorized impeller), includes: Class F, IP 54 & UL-R motor with separate power & control connection cables. Maximum operating temperature -25°to +60° Celsius, speed control, tachometer output; scroll housing with four mounting brackets
Ecofit N19-A4 RREUG9 225 x 50R; 120V, 1-phase, 50-60 Hz. Ecofit EC backward curved motorized impeller includes: motor IP44 and UL-R motor Class F, nominal 150 watt / 3375 rpm max, speed control thru 0-10VDC, operating temperature -25° to +60° Celsius, 900-mm power cable (three wires), 900-mm control cable (speed control three wires & tachometer output 2 wires); high efficiency 225-mm diameter impeller
2RREU35 225X50R, 230-V, 1-phase, 50-60 Hz input voltage. Ecofit AC backward curved motorized impeller, includes: 225-mm high-efficiency galvanized steel impeller; IP44 & UL-R motor Class F with wired-in thermo contact, operating temperature -40 to +70° C
X24-A0 – ECOFIT 2RREU45 250X56R (sealed bearings); 120-volt, 1-phase, 50-60 HZ. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F, with sealed bearings, operating temperature -40° to +60° celsius, 900-mm connection cable on the rear side of the motor; 250-mm diameter galvanized steel impeller. Height C = 102-mm.
X47-A3 – ECOFIT 2RREU45 250X50R; 120-V, 1-phase, 50-60 Hz. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F, operating temperature -40° TO +70° celsius, wired in thermo contact protection, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 102-MM. 1600 CFM at free air (60 HZ).
N06-B1 ECOFIT 2RREU45 250X50R; 230-volt, 1-phase, 50-60 Hz. AC backward curved motorized impeller includes: IP44 & UL-R motor class F, operating temperature -40° to +70° celsius, wired in thermo contact protection, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 102-mm.
U31-A2 ECOFIT 2RREU45 250X50R; 230-volt, 1-phase, 50-60 Hz. AC backward curved motorized impeller includes: IP44 & UL-R motor class F, operating temperature -40° to +70° celsius, wired in thermo contact protection, connection cable on the rear side of the motor; 250-mm diameter High Efficiency Polyamide Impeller. Height C = 102-mm.
P02-A4 – EVOFIT 2RREU45 250X50R; 230-volt, 1-phase, 60 Hz. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F motor, operating temperature -40° TO +55° celsius, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 108-MM
Rosenberg EC Axial Fan, AKFG 800 N.6NA A6 Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 12,000 CFM at 1 inch WG. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Contact Rosenberg USA for more details.
Ecofit 2RREu35 225x50R (PN # M42-A8 Rev. a) 120-Volt AC backward curved motorized impeller, includes: 225-mm high efficiency galvanized steel impeller; IP44 & UL-R motor class f with wired-in thermo contact, operating temperature -40 to +70° C
Ecofit 2RREu35 225x50R (PN # M42-A8 Rev. a) 120-Volt AC backward curved motorized impeller, includes: 225-mm high efficiency galvanized steel impeller; IP44 & UL-R motor class f with wired-in thermo contact, operating temperature -40 to +70° C
ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.
ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.
Ecofit RRMUV8 200X63R, 200-277 input voltage (300 watt max), 1-phase, 50-60 HZ. EC backward curved impeller, IP54 and UL-R Motor Class F, speed controllable, operating temperature -25°C TO +60°C. high efficiency impeller made of galvanized steel, module & inlet cone (without pressure tabs) made of non-painted galvanized steel.
Ecofit RRMUV8 200X63R, 200-277 input voltage (300 watt max), 1-phase, 50-60 HZ. EC backward curved impeller, IP54 and UL-R Motor Class F, speed controllable, operating temperature -25°C TO +60°C. high efficiency impeller made of galvanized steel, module & inlet cone (without pressure tabs) made of non-painted galvanized steel.
Ecofit EC RRMUV8 280X65R, input voltage 200-277 volt (300 watt max), 1-phase, 50-60 Hz. EC backward curved impeller, module construction. Motor IP54 AND UL-R Motor Class F, high-efficiency impeller made of polyamide, module & inlet cone (without pressure tabs) made of unpainted galvanized steel.
Ecofit EC RRMUV8 280X65R, input voltage 200-277 volt (300 watt max), 1-phase, 50-60 Hz. EC backward curved impeller, module construction. Motor IP54 AND UL-R Motor Class F, high-efficiency impeller made of polyamide, module & inlet cone (without pressure tabs) made of unpainted galvanized steel.
Ecofit RREUG9 192 X 40R, 120-volt input voltage (1-phase, 50-60 HZ). Ecofit EC backward curved motorized impeller, includes: UL-R EC motor CLASS F (150 watt / 3930 rpm max ), with speed control, operating temperature -25°C to +60°C; very high efficiency impeller, diameter 192-mm made of PPC-T20 polypropylene UL 94-VO.v
Ecofit RREUG9 192 X 40R, 120-volt input voltage (1-phase, 50-60 HZ). Ecofit EC backward curved motorized impeller, includes: UL-R EC motor CLASS F (150 watt / 3930 rpm max ), with speed control, operating temperature -25°C to +60°C; very high efficiency impeller, diameter 192-mm made of PPC-T20 polypropylene UL 94-VO.
HOT AIR BLOWER – Q41-A4 (2DTRu45 225x40R) backward curved stainless steel impeller. For convection ovens, incubators, kilns, test chambers with extreme temperatures, food/plate warmers. Maximum air temperature on impeller: 300 degrees C. Ball bearings for long service life.
HOT AIR BLOWER – Q41-A4 (2DTRu45 225x40R) backward curved stainless steel impeller. For convection ovens, incubators, kilns, test chambers with extreme temperatures, food/plate warmers. Maximum air temperature on impeller: 300 degrees C. Ball bearings for long service life.
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.