Rosenberg EC Backward Curved Impeller, GKHM 315-CIB.112.6FF IE Gen3, Module Construction, Input Voltage 380-480 Volt (3.65 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC module, GKHM 355-CIW.110.5HF, 3PH, 200-240V, 50/60 HZ., IP54, UL-R, includes inlet cone with pressure-measuring tabs. Supplied in open loop mode. Software for closed loop mode not included.
Rosenberg EC Backward Curved Impeller, GKHM 355-CIB.112.6FF IE Gen3, Module Construction, Input Voltage 200-240 Volt (3 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller, GKHM 355-CIB.112.6FF IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.37 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC backward curved impeller, GKHM 355-CIB.112.5hF IE Gen3, module construction, input voltage 200-240 volt (1.78 kW & 2520 RPM max) and 380-480 volt (2.49 kW & 2840 RPM max), 3-phase, 50-60 Hz. Ip54 and UL-R motor Class F with status led indicator, open loop only (0-10v, PWM, MODBUS, potentiometer), operating temperature -25°c to +40°c at full speed. High efficiency aluminum impeller, 3300 CFM @ 3.3 inWG
Rosenberg EC Backward Curved Impeller, GKHM 400-CIB.125.6FF IE Gen3, Module Construction, Input Voltage 200-240 Volt (2.7 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller, GKHM 400-CIB.125.6FF IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.5 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller, GKHM 450-CIB.140.6IF IE Gen3, Module Construction, Input Voltage 200-240 Volt (3.1 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller, GKHM 450-CIB.140.6IF IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.5 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller, GKHM 500-CIB.160.6IF IE Gen3, Module Construction, Input Voltage 200-240 Volt (2.82 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone
Rosenberg EC Backward Curved Impeller, GKHM 500-CIB.160.6IF IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.5 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone
ROSENBERG EC backward curved impeller, GKHM 500-CIB.160.6NA IE GEN3+, input voltage 200-240 volt (4.2 Kw / 1880 RPM max) and 380-480 volt (7 Kw / 2225 RPM max), 3-phase, 50-60 hz. IP54 and UL-R motor class f with status led indicator, open loop (0-10v, pwm, 4-20 ma, modbus, potentiometer), operating temperature -25°C to +40°C at full speed. module construction with aluminum (ALMG3) high efficiency impeller; front plate (dimensions 700 x 700-mm), motor plate, and inlet cone (with plastic tubing).
ROSENBERG EC backward curved impeller, GKHM 500-CIB.160.6NA IE GEN3+, input voltage 200-240 volt (4.2 Kw / 1880 RPM max) and 380-480 volt (7 Kw / 2225 RPM max), 3-phase, 50-60 hz. IP54 and UL-R motor class f with status led indicator, open loop (0-10v, pwm, 4-20 ma, modbus, potentiometer), operating temperature -25°C to +40°C at full speed. module construction with aluminum (ALMG3) high efficiency impeller; front plate (dimensions 700 x 700-mm), motor plate, and inlet cone (with plastic tubing).
Rosenberg EC Backward Curved Impeller, GKHM 560-CIB.180.6IF IE Gen3, Module Construction, Input Voltage 200-240 Volt (2.3 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller, GKHM 560-CIB.180.6IF IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.05 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
ROSENBERG GKHM 560-CEG.160.6NA IE, input voltage 380-480 volt (5.1 kw max), 3-phase, 50-60 Hz. IP54 and UL-R motor class f, operating temperature -20°c to +40°c, very high efficiency impeller with 6 blades painted quart grey (RAL 7039), galvanized steel inlet cone with pressure measuring tabs & tubing (k factor 234). soft start and maximum rotation speed 1950 RPM. total weight 74 Kg.
Rosenberg EC Backward Curved Impeller, GKHM 630-CIB.200.6NA IE, Module Construction, Input Voltage 200-240 Volt (3.05 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller,GKHM 630-CIB.200.6NA IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.5 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
P02-A4 – EVOFIT 2RREU45 250X50R; 230-volt, 1-phase, 60 Hz. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F motor, operating temperature -40° TO +55° celsius, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 108-MM
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F
2RREU35 225X50R, 230-V, 1-phase, 50-60 Hz input voltage. Ecofit AC backward curved motorized impeller, includes: 225-mm high-efficiency galvanized steel impeller; IP44 & UL-R motor Class F with wired-in thermo contact, operating temperature -40 to +70° C
HOT AIR BLOWER – Q41-A4 (2DTRu45 225x40R) backward curved stainless steel impeller. For convection ovens, incubators, kilns, test chambers with extreme temperatures, food/plate warmers. Maximum air temperature on impeller: 300 degrees C. Ball bearings for long service life.
Ecofit R27-A0 GDSUV8 180x180l constant airflow; 200-277-volt, 1-phase, 50-60 Hz input voltage; Ecofit EC double inlet forward curved blower (motorized impeller), includes: Class F, IP 54 & UL-R motor with separate power & control connection cables. Maximum operating temperature -25°to +60° Celsius, speed control, tachometer output; scroll housing with four mounting brackets
ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.
Ecofit EC RRMUV8 280X65R, input voltage 200-277 volt (300 watt max), 1-phase, 50-60 Hz. EC backward curved impeller, module construction. Motor IP54 AND UL-R Motor Class F, high-efficiency impeller made of polyamide, module & inlet cone (without pressure tabs) made of unpainted galvanized steel.
Ecofit RRMUV8 200X63R, 200-277 input voltage (300 watt max), 1-phase, 50-60 HZ. EC backward curved impeller, IP54 and UL-R Motor Class F, speed controllable, operating temperature -25°C TO +60°C. high efficiency impeller made of galvanized steel, module & inlet cone (without pressure tabs) made of non-painted galvanized steel.