Fans for Power Electronics and VFD
Item | Brand | Fan Type | Motor Type | Special Class | Size | Voltage | Phase | Freq. (Hz) | CFM* Max. Air | DB A | More | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Ecofit | Axial | EC | – | 218 | 115 | 1~ | 60 | 709 | 69 | > V More | ||
Ecofit M29-A3 VGCUG9 200V 120-volt, 1-phase, 50-60 Hz. Ecofit EC tube axial fan (motorized impeller), includes: 150 watts / 3515 rpm max, UL-R & IP44 motor Class F, with separate power & control connection cables (380-mm from the fan housing), operating temperature -25° to +60° celsius, speed control, 200-mm diameter polyamide (PA 6/6, UL94 V0) impeller; square aluminum housing with two mounting flanges dimensions 218 x 218. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Blowers | EC | – | 160 | 115 | 1~ | 60 | 368 | 67 | > V More | ||
Ecofit M36-A6 GREUG9 160x62R; 120V, 1-phase, 50-60 Hz. Ecofit EC single inlet forward curved blower (motorized impeller), standard airflow /pressure output, includes: IP44 & UL-R EC motor Class F, nominal 142 watts & 1910 rpm, with soft start, speed controlable, 900-mm separate power & control connection cables, operating temperature -25°c to +60°c at full speed; impeller made of galvanized steel; scroll housing made of painted or galvanized steel. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | EC | – | 220 | 230 | 1~ | 60 | 710 | 78 | > V More | ||
Ecofit U24-D4 RREUG9 220 x 43R; 230V, 1-phase, 50-60 Hz. Ecofit EC backward curved motorized impeller, includes: IP44 and UL-R motor Class F, nominal 150 watts / 3395 rpm max, operating temperature -20°C to +50°C, 900-mm connection wires (power input three wires, speed control three wires, tachometer output two wires); very high efficiency impeller made of PPC-T20 polypropylene. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Blowers | EC | – | 180 | 230 | 1~ | 60 | 827 | – | > V More | ||
Ecofit R27-A0 GDSUV8 180x180l constant airflow; 200-277-volt, 1-phase, 50-60 Hz input voltage; Ecofit EC double inlet forward curved blower (motorized impeller), includes: Class F, IP 54 & UL-R motor with separate power & control connection cables. Maximum operating temperature -25°to +60° Celsius, speed control, tachometer output; scroll housing with four mounting brackets Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | EC | – | 225 | 115 | 1~ | 60 | 827 | – | > V More | ||
Ecofit N19-A4 RREUG9 225 x 50R; 120V, 1-phase, 50-60 Hz. Ecofit EC backward curved motorized impeller includes: motor IP44 and UL-R motor Class F, nominal 150 watt / 3375 rpm max, speed control thru 0-10VDC, operating temperature -25° to +60° Celsius, 900-mm power cable (three wires), 900-mm control cable (speed control three wires & tachometer output 2 wires); high efficiency 225-mm diameter impeller Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | EC | – | 250 | 230 | 1~ | 60 | 959 | 87 | > V More | ||
Ecofit X48-A3 RREuV8 250x50R backward curved centrifugal fans with 230V, 1-phase, 50-60 Hz. Ecofit EC motor and galvanized steel impeller. Protection level: 54. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 48 | – | – | 147 | 51 | > V More | ||
120x120x38 DC Axial Fan, 48 VDC input, UL 94 V-0 plastic housing and impeller, up to 147 CFM or .64 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 24 | – | – | 147 | 51 | > V More | ||
120x120x38 DC Axial Fan, 24 VDC input, UL 94 V-0 plastic housing and impeller, up to 147 CFM or .64 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 12 | – | – | 147 | 51 | > V More | ||
120x120x38 DC Axial Fan, 12 VDC input, UL 94 V-0 plastic housing and impeller, up to 147 CFM or .64 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 48 | – | – | 129 | 48 | > V More | ||
120x120x38 DC Axial Fan, 48 VDC input, UL 94 V-0 plastic housing and impeller, up to 126 CFM or .53 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 24 | – | – | 129 | 48 | > V More | ||
120x120x38 DC Axial Fan, 24 VDC input, UL 94 V-0 plastic housing and impeller, up to 126 CFM or .53 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 12 | – | – | 129 | 48 | > V More | ||
120x120x38 DC Axial Fan, 12 VDC input, UL 94 V-0 plastic housing and impeller, up to 126 CFM or .53 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 48 | – | – | 112 | 46 | > V More | ||
120x120x38 DC Axial Fan, 48 VDC input, UL 94 V-0 plastic housing and impeller, up to 112 CFM or .38 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 24 | – | – | 112 | 46 | > V More | ||
120x120x38 DC Axial Fan, 24 VDC input, UL 94 V-0 plastic housing and impeller, up to 112 CFM or .38 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 12 | – | – | 112 | 46 | > V More | ||
120x120x38 DC Axial Fan, 12 VDC input, UL 94 V-0 plastic housing and impeller, up to 112 CFM or .38 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 48 | – | – | 104 | 43 | > V More | ||
120x120x38 DC Axial Fan, 48 VDC input, UL 94 V-0 plastic housing and impeller, up to 103.9 CFM or .33 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 24 | – | – | 104 | 43 | > V More | ||
120x120x38 DC Axial Fan, 24 VDC input, UL 94 V-0 plastic housing and impeller, up to 103.9 CFM or .33 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 12 | – | – | 104 | 43 | > V More | ||
120x120x38 DC Axial Fan, 12 VDC input, UL 94 V-0 plastic housing and impeller, up to 103.9 CFM or .33 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 48 | – | – | 83 | 38 | > V More | ||
120x120x38 DC Axial Fan, 48 VDC input, UL 94 V-0 plastic housing and impeller, up to 82.7 CFM or .21 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 24 | – | – | 83 | 38 | > V More | ||
120x120x38 DC Axial Fan, 24 VDC input, UL 94 V-0 plastic housing and impeller, up to 82.7 CFM or .21 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 12 | – | – | 83 | 38 | > V More | ||
120x120x38 DC Axial Fan, 12 VDC input, UL 94 V-0 plastic housing and impeller, up to 82.7 CFM or .21 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 48 | – | – | 57 | 30 | > V More | ||
120x120x38 DC Axial Fan, 48 VDC input, UL 94 V-0 plastic housing and impeller, up to 57 CFM or .1 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 24 | – | – | 57 | 30 | > V More | ||
120x120x38 DC Axial Fan, 24 VDC input, UL 94 V-0 plastic housing and impeller, up to 57 CFM or .1 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | ETRI | Axial | DC | – | 120 | 12 | – | – | 57 | 30 | > V More | ||
120x120x38 DC Axial Fan, 12 VDC input, UL 94 V-0 plastic housing and impeller, up to 57 CFM or .1 inches H20 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 225 | 230 | 1 | 60 | 759 | 72 | > V More | ||
2RREU35 225X50R, 230-V, 1-phase, 50-60 Hz input voltage. Ecofit AC backward curved motorized impeller, includes: 225-mm high-efficiency galvanized steel impeller; IP44 & UL-R motor Class F with wired-in thermo contact, operating temperature -40 to +70° C Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 250 | 115 | 1 | 60 | 1009 | 77 | > V More | ||
X24-A0 – ECOFIT 2RREU45 250X56R (sealed bearings); 120-volt, 1-phase, 50-60 HZ. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F, with sealed bearings, operating temperature -40° to +60° celsius, 900-mm connection cable on the rear side of the motor; 250-mm diameter galvanized steel impeller. Height C = 102-mm. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 250 | 115 | 1 | 60 | 827 | – | > V More | ||
X47-A3 – ECOFIT 2RREU45 250X50R; 120-V, 1-phase, 50-60 Hz. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F, operating temperature -40° TO +70° celsius, wired in thermo contact protection, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 102-MM. 1600 CFM at free air (60 HZ). Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 250 | 230 | 1 | 60 | 947 | 76 | > V More | ||
N06-B1 ECOFIT 2RREU45 250X50R; 230-volt, 1-phase, 50-60 Hz. AC backward curved motorized impeller includes: IP44 & UL-R motor class F, operating temperature -40° to +70° celsius, wired in thermo contact protection, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 102-mm. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 250 | 230 | 1 | 60 | 912 | 67 | > V More | ||
U31-A2 ECOFIT 2RREU45 250X50R; 230-volt, 1-phase, 50-60 Hz. AC backward curved motorized impeller includes: IP44 & UL-R motor class F, operating temperature -40° to +70° celsius, wired in thermo contact protection, connection cable on the rear side of the motor; 250-mm diameter High Efficiency Polyamide Impeller. Height C = 102-mm. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 250 | 230 | 1 | 60 | 1200 | – | > V More | ||
P02-A4 – EVOFIT 2RREU45 250X50R; 230-volt, 1-phase, 60 Hz. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F motor, operating temperature -40° TO +55° celsius, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 108-MM Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | EC | – | 192 | 115 | 1 | 60 | 506 | 74 | > V More | ||
Ecofit RRMuG9 192x40R Backward curved fan module with 120V electronic commutation motor. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | EC | – | 192 | 230 | 1 | 60 | 503 | 74 | > V More | ||
Ecofit RRMuG9 192x40R Backward curved fan module with 230V electronic commutation motor. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 192 | 115 | 1 | 60 | 421 | 65 | > V More | ||
Ecofit RRMuG9 192x40R Backward curved fan module with 115V AC motor. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 192 | 230 | 1 | 60 | 347 | 62 | > V More | ||
Ecofit RRMuG9 192x40R Backward curved fan module with 230V AC motor. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | AC | – | 250 | 230 | 1 | 60 | 1162 | – | > V More | ||
Q13-A0, 2RREu45 250x50R, E-Impeller,1-phase, 230-Volt, Max airflow at free air 1162 CFM, temperature range -4 to +140°f. ERP 2015 compliant. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Ecofit | Backward Curved | EC | – | 250 | 115 | 1 | 60 | 971 | – | > V More | ||
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | EC | – | 280 | 230 | 1 | 60 | 1750 | 80 | > V More | ||
Rosenberg EC fan with B-Wheel impeller, GKH_ 280-CIB.090.4EA-IE, available as fan module or motorized impeller Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 450 | 575 | 3 | 60 | 4865 | – | > V More | ||
ROSENBERG DKHR 450-4SW.138.6FA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 500 | 230-460 | 3 | 60 | 7100 | – | > V More | ||
ROSENBERG DKHR 500-4SW.155.6LA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 560 | 575 | 3 | 60 | 8800 | – | > V More | ||
ROSENBERG DKHR 560-4SW.174.7NA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 560 | 230-460 | 3 | 60 | 9100 | – | > V More | ||
ROSENBERG DKHR 560-4SW.155.7NA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 630 | 460 | 3 | 60 | 9300 | – | > V More | ||
ROSENBERG DKHR 630-6SW.195.7KF 8-blade impeller constructed from sea-waterproof aluminum. Quality class G 2.5, DIN/ISO 1940. Maintenance free ball bearings. Standard external rotor motors. Protection class IP 44/54. CE, UL and RoHS approved. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 355 | 115 | 1 | 60 | 2052 | – | > V More | ||
ROSENBERG EKHR 355-4SW.110.5FA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 355 | 230-460 | 3 | 60 | 2240 | – | > V More | ||
ROSENBERG DKHR 355-4SW.110.5DF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 400 | 230 | 1 | 60 | 2960 | – | > V More | ||
ROSENBERG EKHR 400-4SW.123.5HA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 450 | 230-460 | 3 | 60 | 5000 | – | > V More | ||
ROSENBERG DKHR 450-4SW.138.6HF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 315 | 230-460 | 3 | 60 | 2190 | – | > V More | ||
ROSENBERG DKHR 315-2SW.070.5HA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 355 | 230 | 1 | 60 | 2574 | – | > V More | ||
ROSENBERG DKHR 355-2SW.078.6HF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 310 | 230 | 1 | 60 | 1290 | – | > V More | ||
310-mm (12” diameter) / 1-phase EKHR 310-4SH.100.4EC with glass fiber reinforced polyamide impeller Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
![]() | Rosenberg | Backward Curved | AC | – | 315 | 230-460 | 3 | 60 | 2765 | – | > V More | ||
ROSENBERG DKHR 315-2SW.098.6FA Contact Rosenberg USA for more details. | Get More Information: |