M14-A2

M14-A2
Image Product Brand Fan Type Motor Type Special Class Size Voltage Phase Freq. (Hz) CFM* Max. Air DB A More
M14-A2 M14-A2 Ecofit Blowers AC 180 115 1 60 795 57

ECOFIT 4GDFU65 180X180L, 115-Volt, 1-phase, 4-pole motor, 270-Watt power consumption and 795 cfm @ free air, up to 1.4” of water pressure (no air), sound pressure 57 dB(A), non-flange scroll housing

ECOFIT 4GDFU65 180X180L, 115-Volt, 1-phase, 4-pole motor, 270-Watt power consumption and 795 cfm @ free air, up to 1.4” of water pressure (no air), sound pressure 57 dB(A), non-flange scroll housing

Contact Rosenberg USA for more details.

M15-A0 M15-A0 Ecofit Blowers EC 160 115 1 60 280

GREuG9 160X62R (PN # M15-A0), EC, 120-Volt, 1-phase, Constant Airflow, airflow up to 280 cfm or up to 2.7” of static pressure

GREuG9 160X62R (PN # M15-A0), EC, 120-Volt, 1-phase, Constant Airflow, airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M21-A1 M21-A1 Ecofit Blowers EC 160 230 1 60 364

GREuG9 160x62R (PN # M21-A1), EC, 230-Volt, 1-phase, Standard Airflow-Pressure; airflow up to 364 cfm or up to 2.8” of static pressure “

GREuG9 160x62R (PN # M21-A1), EC, 230-Volt, 1-phase, Standard Airflow-Pressure; airflow up to 364 cfm or up to 2.8” of static pressure ”

Contact Rosenberg USA for more details.

M22-A8 M22-A8 Ecofit Blowers EC 146 230 1 60 500 58

GDSuG9 146x188R (PN # M22-A8), EC, 230-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

GDSuG9 146x188R (PN # M22-A8), EC, 230-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

Contact Rosenberg USA for more details.

M27-A4 M27-A4 Ecofit Blowers EC 146 230 1 60 565 59

GDSuG9 146x188R (PN # M27-A4), EC, 230-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

GDSuG9 146x188R (PN # M27-A4), EC, 230-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

Contact Rosenberg USA for more details.

M36-A4 M36-A4 Ecofit Blowers EC 160 230 1 60 280

GREuG9 160x62R (PN # M36-A4), 230-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure

GREuG9 160x62R (PN # M36-A4), 230-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M36-A5 M36-A5 Ecofit Blowers EC 160 230 1 60 280

GREuG9 160x62R (PN # M36-A5), 230-Volt, 1-phase, Constant Airflow; airflow up to 280 cfm or up to 2.7” of static pressure

GREuG9 160x62R (PN # M36-A5), 230-Volt, 1-phase, Constant Airflow; airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M36-A7 M36-A7 Ecofit Blowers EC 160 115 1 60 280

GREuG9 160x62R (PN # M36-A7), 120-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure

GREuG9 160x62R (PN # M36-A7), 120-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M41-A0 M41-A0 Ecofit Blowers AC 133 115 1 60 313

M41-A0: 2GDSu35 133x190R (133-mm diameter impeller / 115-Volt) – Salt Spray, 3-Speed, single phase, ErP 2015 compliant

M41-A0: 2GDSu35 133x190R (133-mm diameter impeller / 115-Volt) – Salt Spray, 3-Speed, single phase, ErP 2015 compliant

Contact Rosenberg USA for more details.

N11-A2 N11-A2 Ecofit Blowers EC 146 115 1 60 565 59

GDSuG9 146x188R (PN # N11-A2), EC, 120-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

GDSuG9 146x188R (PN # N11-A2), EC, 120-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

Contact Rosenberg USA for more details.

N17-A5 N17-A5 Ecofit Blowers EC 146 115 1 60 500 58

GDSuG9 146x188R (PN # N17-A5), EC, 120-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

GDSuG9 146x188R (PN # N17-A5), EC, 120-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

Contact Rosenberg USA for more details.

N23-A8 N23-A8 Ecofit Blowers EC 146 115 1 60 500 58

GDSuG9 146x188R (PN # N23-A8), EC, 120-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

GDSuG9 146x188R (PN # N23-A8), EC, 120-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

Contact Rosenberg USA for more details.

N24-B2 N24-B2 Ecofit Blowers AC 133 115 1 60 300

N24-B2: 2GDSu25 133x190R (133-mm diameter impeller, 3-speed, 115-Volt, 1-phase, ERP 2015)

N24-B2: 2GDSu25 133x190R (133-mm diameter impeller, 3-speed, 115-Volt, 1-phase, ERP 2015)

Contact Rosenberg USA for more details.

Q13-A0 Q13-A0 Ecofit Backward Curved AC 250 230 1 60 1038 71

Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.

Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.

Contact Rosenberg USA for more details.

Q13-A1 Q13-A1 Ecofit Backward Curved AC 250 115 1 60 1059 71

Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.

Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.

Contact Rosenberg USA for more details.

Q13-A2 Q13-A2 Ecofit Backward Curved AC 250 230 1 60 1162

Q13-A0, 2RREu45 250x50R, E-Impeller,1-phase, 230-Volt, Max airflow at free air 1162 CFM, temperature range -4 to +140°f. ERP 2015 compliant.

Q13-A0, 2RREu45 250x50R, E-Impeller,1-phase, 230-Volt, Max airflow at free air 1162 CFM, temperature range -4 to +140°f. ERP 2015 compliant.

Contact Rosenberg USA for more details.

Q13-A7 Q13-A7 Ecofit Backward Curved EC 250 115 1 60 971

Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F

Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F

Contact Rosenberg USA for more details.

Q37-B1 Q37-B1 Ecofit Blowers EC 262 230 1 60 1015

Q37-B1 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Standard Airflow/Pressure model; CE-only, ERP 2015 compliant, 557 CFM @ 2.2″, 1015 CFM @ free air

Q37-B1 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Standard Airflow/Pressure model; CE-only, ERP 2015 compliant, 557 CFM @ 2.2″, 1015 CFM @ free air

Contact Rosenberg USA for more details.

Q37-B2 Q37-B2 Ecofit Blowers EC 262 230 1 60 824

Q37-B2 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Constant Airflow Model; CE-only, ERP 2015 compliant, 510 CFM @ 1.8″, 824 CFM @ free air

Q37-B2 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Constant Airflow Model; CE-only, ERP 2015 compliant, 510 CFM @ 1.8″, 824 CFM @ free air

Contact Rosenberg USA for more details.

Q37-B3 Q37-B3 Ecofit Blowers EC 262 230 1 60 1010

Q37-B3 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Constant Pressure model; CE-only, ERP 2015 compliant, 500 CFM @ 1.7″, 1010 CFM @ free air

Q37-B3 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Constant Pressure model; CE-only, ERP 2015 compliant, 500 CFM @ 1.7″, 1010 CFM @ free air

Contact Rosenberg USA for more details.

Q41-A4 Q41-A4 Ecofit Backward Curved AC 225 230 1 60 740

HOT AIR BLOWER – Q41-A4 (2DTRu45 225x40R) backward curved stainless steel impeller. For convection ovens, incubators, kilns, test chambers with extreme temperatures, food/plate warmers. Maximum air temperature on impeller: 300 degrees C. Ball bearings for long service life.

HOT AIR BLOWER – Q41-A4 (2DTRu45 225x40R) backward curved stainless steel impeller. For convection ovens, incubators, kilns, test chambers with extreme temperatures, food/plate warmers. Maximum air temperature on impeller: 300 degrees C. Ball bearings for long service life.

Contact Rosenberg USA for more details.

T11-38 T11-38 Ecofit Blowers AC 130 115 60 294 61

ECOFIT 2GREU25 140X59R, 115VAC, 50/60 HZ. SINGLE INLET

ECOFIT 2GREU25 140X59R, 115VAC, 50/60 HZ. SINGLE INLET

Contact Rosenberg USA for more details.

 

U24-A6 U24-A4 Ecofit Backward Curved AC 192 115 1 60 421 65

Ecofit 2RREu15 192x40R (115V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Ecofit 2RREu15 192x40R (115V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Contact Rosenberg USA for more details.

U24-B1 U24-B1 Ecofit Backward Curved AC 192 230 1 60 390 64

Ecofit 2RREu15 192x40R (230V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Ecofit 2RREu15 192x40R (230V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Contact Rosenberg USA for more details.

U24-C4 U24-C4 Ecofit Backward Curved AC 220 115 1 60 553 67

Ecofit 2RREu25 220x43R (115V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Ecofit 2RREu25 220x43R (115V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Contact Rosenberg USA for more details.

U24-C5 U24-C5 Ecofit Backward Curved AC 220 230 1 60 586 66

Ecofit 2RREu25 220x43R (230V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Ecofit 2RREu25 220x43R (230V) backward curved centrifugal fan with single phase asynchronous motor and high-efficiency E-Wheel impeller

Contact Rosenberg USA for more details.

Y06-08 Y06-08 Ecofit Backward Curved AC 280 230 60 948 65

ECOFIT 4RREU35 280X80R, 230 VAC, 50/60 HZ, UL-R, 948 CFM AT FREE AIR

ECOFIT 4RREU35 280X80R, 230 VAC, 50/60 HZ, UL-R, 948 CFM AT FREE AIR

Contact Rosenberg USA for more details.

Y06-09 Y06-09 Ecofit Backward Curved AC 315 230 60 1265 64

ECOFIT 4RREU45 315X101R, BACKWARD CURVED IMPELLER

ECOFIT 4RREU45 315X101R, BACKWARD CURVED IMPELLER

Contact Rosenberg USA for more details.

Z03-01 Z03-01 Ecofit Blowers AC 146 115 1 60 518

Ecofit Z03-01: 4GDSu35 146x180L (146-mm impeller diameter, 115-Volt, 1-phase, 3-speed model, ERP 2015 compliant)

Ecofit Z03-01: 4GDSu35 146x180L (146-mm impeller diameter, 115-Volt, 1-phase, 3-speed model, ERP 2015 compliant)

Contact Rosenberg USA for more details.

Z18-04 Z18-04 Ecofit Blowers AC 232 230 60 335 56

ECOFIT 2GDS35 133X190L, 230VOLT, 50/60 HZ., 335 CFM AT FREE AIR OPERATING AT 60 HZ., SEE ALSO L23-A6

ECOFIT 2GDS35 133X190L, 230VOLT, 50/60 HZ., 335 CFM AT FREE AIR OPERATING AT 60 HZ., SEE ALSO L23-A6

Contact Rosenberg USA for more details.

Z27-03 Z27-03 Ecofit Backward Curved AC 250 230 60 1027 77

ECOFIT 2RREU45 250X56R, 230VAC 60 HZ, CLASS F-UL

ECOFIT 2RREU45 250X56R, 230VAC 60 HZ, CLASS F-UL

Contact Rosenberg USA for more details.

U24-A6 U24-A6 Ecofit Backward Curved EC 192 115 1 60 506 74

Ecofit RREUG9 192 X 40R, 120-volt input voltage (1-phase, 50-60 HZ). Ecofit EC backward curved motorized impeller, includes: UL-R EC motor CLASS F (150 watt / 3930 rpm max ), with speed control, operating temperature -25°C to +60°C; very high efficiency impeller, diameter 192-mm made of PPC-T20 polypropylene UL 94-VO.v

Ecofit RREUG9 192 X 40R, 120-volt input voltage (1-phase, 50-60 HZ). Ecofit EC backward curved motorized impeller, includes: UL-R EC motor CLASS F (150 watt / 3930 rpm max ), with speed control, operating temperature -25°C to +60°C; very high efficiency impeller, diameter 192-mm made of PPC-T20 polypropylene UL 94-VO.

Contact Rosenberg USA for more details.

S03-A3 S03-A3 Ecofit Backward Curved 280 230 1 60 876

Ecofit EC RRMUV8 280X65R, input voltage 200-277 volt (300 watt max), 1-phase, 50-60 Hz. EC backward curved impeller, module construction. Motor IP54 AND UL-R Motor Class F, high-efficiency impeller made of polyamide, module & inlet cone (without pressure tabs) made of unpainted galvanized steel.

Ecofit EC RRMUV8 280X65R, input voltage 200-277 volt (300 watt max), 1-phase, 50-60 Hz. EC backward curved impeller, module construction. Motor IP54 AND UL-R Motor Class F, high-efficiency impeller made of polyamide, module & inlet cone (without pressure tabs) made of unpainted galvanized steel.

Contact Rosenberg USA for more details.

T21-A2 T21-A2 Ecofit Backward Curved 200 230 3 60 690

Ecofit RRMUV8 200X63R, 200-277 input voltage (300 watt max), 1-phase, 50-60 HZ. EC backward curved impeller, IP54 and UL-R Motor Class F, speed controllable, operating temperature -25°C TO +60°C. high efficiency impeller made of galvanized steel, module & inlet cone (without pressure tabs) made of non-painted galvanized steel.

Ecofit RRMUV8 200X63R, 200-277 input voltage (300 watt max), 1-phase, 50-60 HZ. EC backward curved impeller, IP54 and UL-R Motor Class F, speed controllable, operating temperature -25°C TO +60°C. high efficiency impeller made of galvanized steel, module & inlet cone (without pressure tabs) made of non-painted galvanized steel.

Contact Rosenberg USA for more details.

T42-A4 T42-A4 Ecofit Backward Curved EC 180 230 1 60 394

Ecofit backward-curved centrifugal fan, 7.09 inches electronic commutation motor

Ecofit backward-curved centrifugal fan, 7.09 inches electronic commutation motor

Contact Rosenberg USA for more details.

S35-A1 S35-A1 Ecofit Blowers EC 146 115 1 60 530

Ecofit EC double inlet blower with EC motor, GDSUG9 146X188R, 120V, 1 PH, 50/60 Hz, UL-R motor, black painted scroll housing with flange, standard

Ecofit EC double inlet blower with EC motor, GDSUG9 146X188R, 120V, 1 PH, 50/60 Hz, UL-R motor, black painted scroll housing with flange, standard airflow pressure model.

Contact Rosenberg USA for more details.

V32-A1 p V32-A1 p Ecofit Backward Curved AC 192 230 1 60 347 62

Ecofit RRMuG9 192x40R Backward curved fan module with 230V AC motor. Lightweight plastic module guarantees high ventilation efficiency with minimal loss of airflow caused by the assembly, and no increase in noise or vibrations.

Ecofit RRMuG9 192x40R Backward curved fan module with 230V AC motor.

Contact Rosenberg USA for more details.

V32-A2 p V32-A2 p Ecofit Backward Curved AC 192 115 1 60 421 65

Ecofit RRMuG9 192x40R Backward curved fan module with 115V AC motor. Lightweight plastic module guarantees high ventilation efficiency with minimal loss of airflow caused by the assembly, and no increase in noise or vibrations.

Ecofit RRMuG9 192x40R Backward curved fan module with 115V AC motor.

Contact Rosenberg USA for more details.

V32-A4-1 V32-A4-1 Ecofit Backward Curved EC 192 230 1 60 503 74

Ecofit RRMuG9 192x40R Backward curved fan module with 230V electronic commutation motor. Lightweight plastic module guarantees high ventilation efficiency with minimal loss of airflow caused by the assembly, and no increase in noise or vibrations.

Ecofit RRMuG9 192x40R Backward curved fan module with 230V electronic commutation motor.

Contact Rosenberg USA for more details.

V32-A5-1 V32-A5-1 Ecofit Backward Curved EC 192 115 1 60 506 74

Ecofit RRMuG9 192x40R Backward curved fan module with 120V electronic commutation motor. Lightweight plastic module guarantees high ventilation efficiency with minimal loss of airflow caused by the assembly, and no increase in noise or vibrations.

Ecofit RRMuG9 192x40R Backward curved fan module with 120V electronic commutation motor.

Contact Rosenberg USA for more details.

S03-A2 Rev. a S03-A2 Rev. a Ecofit Blowers AC 120X126L 115 1 60 235 57

ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.

ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.

Contact Rosenberg USA for more details.

M42-A8 Rev. a M42-A8 Rev. a Ecofit Backward Curved AC 225 115 1 60 780

Ecofit 2RREu35 225x50R (PN # M42-A8 Rev. a) 120-Volt AC backward curved motorized impeller, includes: 225-mm high efficiency galvanized steel impeller; IP44 & UL-R motor class f with wired-in thermo contact, operating temperature -40 to +70° C

Ecofit 2RREu35 225x50R (PN # M42-A8 Rev. a) 120-Volt AC backward curved motorized impeller, includes: 225-mm high efficiency galvanized steel impeller; IP44 & UL-R motor class f with wired-in thermo contact, operating temperature -40 to +70° C

Contact Rosenberg USA for more details.

S27-A2 p S27-A2 p Ecofit Backward Curved AC 225 230 1 60 668 72

Ecofit 2RREU45 225X50R HES, 230V, 1-PHASE, 50-60 Hz input voltage. Ecofit AC backward curved motorized impeller, includes: 225-mm high efficiency galvanized steel impeller; IP44 & UL-R motor class F.

Ecofit 2RREU45 225X50R HES, 230V, 1-PHASE, 50-60 Hz input voltage. Ecofit AC backward curved motorized impeller, includes: 225-mm high efficiency galvanized steel impeller; IP44 & UL-R motor class F.

Contact Rosenberg USA for more details.

Q08-A8 Rev. b Q08-A8 Rev. b Ecofit Backward Curved AC 250 115 1 60 990

Ecofit 2RREu45 250X50R, 115V, 1-phase, 50-60 Hz, IP44 & UL-R motor, high efficiency metal impeller, ERP 2015

Ecofit 2RREu45 250X50R, 115V, 1-phase, 50-60 Hz, IP44 & UL-R motor, high efficiency metal impeller, ERP 2015

Contact Rosenberg USA for more details.

H03-A0 H03-A0 Ecofit Backward Curved AC 133 230 1 60 215

Ecofit 2RREUA3 133X42R, input voltage 230V, 1-PHASE, 50-60 HZ. Ecofit AC backward curved motorized impeller: IP44 & UL-R motor class F; plastic impeller PBT-GF30 (UL 94-V0) with metal back plate

Ecofit 2RREUA3 133X42R, input voltage 230V, 1-PHASE, 50-60 HZ. Ecofit AC backward curved motorized impeller: IP44 & UL-R motor class F; plastic impeller PBT-GF30 (UL 94-V0) with metal back plate

Contact Rosenberg USA for more details.

U24-D5 U24-D5 Ecofit Backward Curved EC 220 115 1 60 706

Ecofit RREUG9 220 X 43R, 120v 1-PHASE, 50-60 Hz. EC backward curved impeller includes: motor ip44 and ul-r motor class f, and very high efficiency impeller diameter 220-mm made of ppc-t20 polypropylene.

Ecofit RREUG9 220 X 43R, 120v 1-PHASE, 50-60 Hz. EC backward curved impeller includes: motor ip44 and ul-r motor class f, and very high efficiency impeller diameter 220-mm made of ppc-t20 polypropylene.

Contact Rosenberg USA for more details.

X48-A3 X48-A3 Ecofit Backward Curved EC 250 230 1~ 60 959 87

Ecofit X48-A3 RREuV8 250x50R backward curved centrifugal fans with 230V, 1-phase, 50-60 Hz. Ecofit EC motor and galvanized steel impeller. Protection level: 54.

Contact Rosenberg USA for more details.

N19-A4 N19-A4 Ecofit Backward Curved EC 225 115 1~ 60 827

Ecofit N19-A4 RREUG9 225 x 50R; 120V, 1-phase, 50-60 Hz. Ecofit EC backward curved motorized impeller includes: motor IP44 and UL-R motor Class F, nominal 150 watt / 3375 rpm max, speed control thru 0-10VDC, operating temperature -25° to +60° Celsius, 900-mm power cable (three wires), 900-mm control cable (speed control three wires & tachometer output 2 wires); high efficiency 225-mm diameter impeller

Contact Rosenberg USA for more details.

R27-A0 R27-A0 Ecofit Blowers EC 180 230 1~ 60 827

Ecofit R27-A0 GDSUV8 180x180l constant airflow; 200-277-volt, 1-phase, 50-60 Hz input voltage; Ecofit EC double inlet forward curved blower (motorized impeller), includes: Class F, IP 54 & UL-R motor with separate power & control connection cables. Maximum operating temperature -25°to +60° Celsius, speed control, tachometer output; scroll housing with four mounting brackets

Contact Rosenberg USA for more details.

U24-D4 U24-D4 Ecofit Backward Curved EC 220 230 1~ 60 710 78

Ecofit U24-D4 RREUG9 220 x 43R; 230V, 1-phase, 50-60 Hz. Ecofit EC backward curved motorized impeller, includes: IP44 and UL-R motor Class F, nominal 150 watts / 3395 rpm max, operating temperature -20°C to +50°C, 900-mm connection wires (power input three wires, speed control three wires, tachometer output two wires); very high efficiency impeller made of PPC-T20 polypropylene.

Contact Rosenberg USA for more details.

Go to Top