Fans for Air Filtration

  • ECOFIT 4RREU35 280X80R, 115 VAC, 280MM DIAMETER, 944 CFM AT FREE AIR
  • ECOFIT 4RREU45 315X101R, 115VAC, 50/60 HZ., 1194 CFM AT FREE AIR
  • ECOFIT 2RREU15 180X35R, 115VAC, 50/60 HZ., 330 CFM AT FREE AIR
  • ECOFIT 2RREU45 225X63R, 115VAC, 225MM DIAMETER, 923 CFM AT FREE AIR
  • ECOFIT 2RREU15 192X40R, 115 VOLT, 60 HZ
  • ECOFIT RRE24 192X40R, 24VDC, 310CFM@0"SP
  • ECOFIT 2RREU15 180X35R, 230V, 1 PH, 60 HZ, BACKWARD CURVED, UL
  • ECOFIT 2RREU35 225X63R, 230V/UL/50-60HZ/60°C MAX TEMP, 775CFM@0" S.P.
  • ECOFIT 2RREU45 250X56R, 220VAC, 50/60 HZ, 1 PH, DROP IN, UL-R, BC IMPELLER, 850 CFM AT FREE AIR
  • ECOFIT 2RREU45 280X40R, 230V, 50/60 HZ., 1PH, DROP IN, UL-R, BC IMPELLER, 938 CFM AT FREE AIR.
  • ECOFIT 2RREU35 225X63R, 230V, 56/60 HZ., 603 CFM AT FREE AIR. CABLE IS TIED TO THE OUTSIDE OF THE FINGERGUARD
  • ECOFIT 2RREU15 192X40R, 115 VAC, 50/60HZ, 1PH, DROP IN, UL-R BC IMPELLER, 270 CFM AT FREE AIR
  • ECOFIT 2RREU45 250X56R, 115 VAC, 50/60 HZ, 1PH, DROP IN, UL-R, BC IMPELLER, 894 CFM AT FREE AIR
  • ECOFIT 2RREU45 280X40R, 115VAC, 50/60 HZ, 1PH, DROP IN, UL-R, BC IMPELLER, 932 CFM AT FREE AIR
  • ECOFIT RRE24 220X45R, 24VDC, CE, BC IMPLELLER, 565 CFM AT FREE AIR
  • ECOFIT 2VGCU25 200V,115VAC, 50/60 HZ, 1PH, CE, COMPACT AXIAL FAN, 555 CFM AT FREE AIR
  • ECOFIT 2VGCU25 200V, 230VAC, 50/60HZ, 1 PH, CE, COMPACT AXIAL FAN, 555 CFM AT FREE AIR
  • Rosenberg double-inlet DRAD 200-4B forward curved AC blower; Wheel width 200 mm; 341W x 318D x 400H; 230-460, 3~ , 50/60 Hz; 1,400 cfm @ 0.7”

  • Rosenberg DRAD 240-4L double-width AC forward curved blower; wheel width 240 mm; 378W x 368D x 400H; IP54 Protection; Voltage: 460, 3~, 60 Hz; 2,500 cfm @ 0.8”

  • Rosenberg double-inlet DRAD 251-4L forward curved AC blower; Wheel width 251 mm; body dimensions 378W x 400D x 443H; 230-460, 3~ , 50/60 Hz; 2,500 cfm @ 1”

  • Rosenberg DRAD 279-4 double-width AC forward curved blower; wheel width 279 mm; 378W x 402 x 443H; IP54 Protection; Voltage: 230-460, 3~, 60 Hz; 3,200 cfm @ 1”

  • Rosenberg double-inlet DRAD 281-4 forward curved AC blower; Wheel width 281 mm; body dimensions 378W x 470D x 523H; 230-460, 3~ , 50/60 Hz; 3,300 cfm @ 1.4”

  • Rosenberg DRAD 315-4 double-width AC forward curved blower; wheel width 315 mm; 462W x 536 x 638H; Voltage: 230-460, 3~, 60 Hz; 4,000 cfm @ 2.1”, 5,600 cfm @ 1.15” of pressure

  • ECOFIT 4RREU25 250X56R, 1/230V/50-60HZ, BASED ON Z19-02 BUT WITH UL-CLASS F
  • ECOFIT 4RREU15 220X45R, UL VERSION, 115V, 60 HZ., 1 PH, 280 CFM@0.2"SP.
  • ECOFIT 4GDFU65180X180L, BASED ON R10-05, 115 VOLT, UL, 1 PHASE
  • ECOFIT RRED7 225X63R, 230V, 1 PH

  • ECOFIT 2RRE45 280X40R, 230 V, 50/60 HZ., BASED ON Z19-07 BUT WITH A CATAPHORESIS ON THE ROTOR, ROTOR PAINTED INSIDE. VARNISH ON WINDING CONNECTION, SEALED BALL BEARINGS
  • ECOFIT 2RREU25 220X45R, 230V, 1 PH, 60 HZ
  • J12-A8: 2GDSu25 133x190R (133-mm diameter impeller / 230-Volt) 3-speed model, 1-phase, ERP 2015 compliant
  • J40-A2: 2GDSu15 120x126L (120-mm diameter impeller, 115-Volt, 1-phase, 3-speed model, ERP 2015 compliant)

  • ECOFIT 2RREU45 250X56R, 115VAC, 50/60 HZ, 1 PH, DROP-IN, UL-R, 894 CFM AT FREE AIR, 3 SPEED (LOW 50%, MEDIUM 75%, HIGH 100 %)
  • ECOFIT 2GDFUT65 146X180L DOUBLE INLET CENTRIFUGAL FAN BASED ON C03-A3, 400 TO 460V, 3 PH, 60 HZ.M BUT WITH PAINTED ROTOR. INDIVIDUALLY PACKED.
  • ECOFIT 2GDSU35 133X190R, 3 SPEED. HIGH SPEED: 100V, 2.8 A, MEDIUM SPEED: 80V, 2.2 A, LOW SPEED: 70V, 2 A
  • GDSuG9 146x188R (PN # M10-A2), EC, 230-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

  • ECOFIT 4GDFU65 180X180L, 115-Volt, 1-phase, 4-pole motor, 270-Watt power consumption and 795 cfm @ free air, up to 1.4” of water pressure (no air), sound pressure 57 dB(A), non-flange scroll housing
  • GREuG9 160X62R (PN # M15-A0), EC, 120-Volt, 1-phase, Constant Airflow, airflow up to 280 cfm or up to 2.7” of static pressure
  • GREuG9 160x62R (PN # M21-A1), EC, 230-Volt, 1-phase, Standard Airflow-Pressure; airflow up to 364 cfm or up to 2.8” of static pressure "
  • GREuG9 160x62R (PN # M36-A4), 230-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure
  • GREuG9 160x62R (PN # M36-A5), 230-Volt, 1-phase, Constant Airflow; airflow up to 280 cfm or up to 2.7” of static pressure
  • GREuG9 160x62R (PN # M36-A7), 120-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure
  • M41-A0: 2GDSu35 133x190R (133-mm diameter impeller / 115-Volt) – Salt Spray, 3-Speed, single phase, ErP 2015 compliant
  • GDSuG9 146x188R (PN # N17-A5), EC, 120-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

  • N24-B2: 2GDSu25 133x190R (133-mm diameter impeller, 3-speed, 115-Volt, 1-phase, ERP 2015)
  • Rosenberg model GKHM 280-CIE.065.4EA IE HP fan module with high-efficiency 120-V / 1-Phase 400 Watt EC motor and super quiet impeller made of glass fiber reinforced polyamide. 1000 cfm @ 2”
  • Rosenberg model GKHM 280-CIE.065.4EA IE HP fan module with high-efficiency 120-V / 1-Phase 400 Watt EC motor and super quiet impeller made of glass fiber reinforced polyamide. 1000 cfm @ 1.9”
  • ROSENBERG DKHR 225-2SW.070.4EC
  • ROSENBERG DKHR 225-2SW.070.4EC
  • ROSENBERG EKHR 225-2SW.070.4FF
  • ROSENBERG EKHR 225-2SW.070.4FF
Go to Top