Ecofit EC RRMUV8 280X65R, input voltage 200-277 volt (300 watt max), 1-phase, 50-60 Hz. EC backward curved impeller, module construction. Motor IP54 AND UL-R Motor Class F, high-efficiency impeller made of polyamide, module & inlet cone (without pressure tabs) made of unpainted galvanized steel.
Ecofit EC RRMUV8 280X65R, input voltage 200-277 volt (300 watt max), 1-phase, 50-60 Hz. EC backward curved impeller, module construction. Motor IP54 AND UL-R Motor Class F, high-efficiency impeller made of polyamide, module & inlet cone (without pressure tabs) made of unpainted galvanized steel.
ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.
ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.
Ecofit R27-A0 GDSUV8 180x180l constant airflow; 200-277-volt, 1-phase, 50-60 Hz input voltage; Ecofit EC double inlet forward curved blower (motorized impeller), includes: Class F, IP 54 & UL-R motor with separate power & control connection cables. Maximum operating temperature -25°to +60° Celsius, speed control, tachometer output; scroll housing with four mounting brackets
2RREU35 225X50R, 230-V, 1-phase, 50-60 Hz input voltage. Ecofit AC backward curved motorized impeller, includes: 225-mm high-efficiency galvanized steel impeller; IP44 & UL-R motor Class F with wired-in thermo contact, operating temperature -40 to +70° C
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
P02-A4 – EVOFIT 2RREU45 250X50R; 230-volt, 1-phase, 60 Hz. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F motor, operating temperature -40° TO +55° celsius, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 108-MM
Rosenberg EC Backward Curved Impeller, GKHM 630-CIB.200.6NA IE, Module Construction, Input Voltage 200-240 Volt (3.05 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller, GKHM 630-CIB.200.6NA IE, Module Construction, Input Voltage 200-240 Volt (3.05 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller,GKHM 630-CIB.200.6NA IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.5 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)
Rosenberg EC Backward Curved Impeller,GKHM 630-CIB.200.6NA IE Gen3, Module Construction, Input Voltage 380-480 Volt (4.5 Kw), 3-Phase, 50-60 Hz. High-efficiency impeller made of aluminum, module and inlet cone (with plastic tubing and pressure tabs)