HOT AIR BLOWER – Q41-A4 (2DTRu45 225x40R) backward curved stainless steel impeller. For convection ovens, incubators, kilns, test chambers with extreme temperatures, food/plate warmers. Maximum air temperature on impeller: 300 degrees C. Ball bearings for long service life.
HOT AIR BLOWER – Q41-A4 (2DTRu45 225x40R) backward curved stainless steel impeller. For convection ovens, incubators, kilns, test chambers with extreme temperatures, food/plate warmers. Maximum air temperature on impeller: 300 degrees C. Ball bearings for long service life.
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F
Ecofit RRMUG9 250X50R, input voltage 120 V (150 Watt max), 1-PHASE, 50-60 HZ. EC backward curved impeller, module construction (296 x 296-MM). motor IP44 and UL-R motor class F
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM – airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.
GDSuG9 146x188R (PN # N23-A8), EC, 120-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”
GDSuG9 146x188R (PN # N23-A8), EC, 120-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”
GDSuG9 146x188R (PN # M22-A8), EC, 230-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”
GDSuG9 146x188R (PN # M22-A8), EC, 230-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”
ECOFIT 4GDFU65 180X180L, 115-Volt, 1-phase, 4-pole motor, 270-Watt power consumption and 795 cfm @ free air, up to 1.4” of water pressure (no air), sound pressure 57 dB(A), non-flange scroll housing
ECOFIT 4GDFU65 180X180L, 115-Volt, 1-phase, 4-pole motor, 270-Watt power consumption and 795 cfm @ free air, up to 1.4” of water pressure (no air), sound pressure 57 dB(A), non-flange scroll housing
ECOFIT 2GDSU15 120X126L115VAC, 50/60 HZM, SPECIAL AIR OUTPUT FOR HEAT SINK APPLICATIONS ACCORING TO ECOFIT DRAWING PDR10-140-0, CAPACITOR ASSEMBLY ON THE AIR OUTPUT, WAGO CONNECTOR ASSEMBLY ON THE SCROLL AND FINGERGUARDS.
ECOFIT 2GDSU15 120X126L115VAC, 50/60 HZM, SPECIAL AIR OUTPUT FOR HEAT SINK APPLICATIONS ACCORING TO ECOFIT DRAWING PDR10-140-0, CAPACITOR ASSEMBLY ON THE AIR OUTPUT, WAGO CONNECTOR ASSEMBLY ON THE SCROLL AND FINGERGUARDS.
ECOFIT 2RRE45 280X40R, 230 V, 50/60 HZ., BASED ON Z19-07 BUT WITH A CATAPHORESIS ON THE ROTOR, ROTOR PAINTED INSIDE. VARNISH ON WINDING CONNECTION, SEALED BALL BEARINGS
ECOFIT 2RRE45 280X40R, 230 V, 50/60 HZ., BASED ON Z19-07 BUT WITH A CATAPHORESIS ON THE ROTOR, ROTOR PAINTED INSIDE. VARNISH ON WINDING CONNECTION, SEALED BALL BEARINGS
ECOFIT 4GDFU65 200X200L, BASED ON F21-A2, 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES – 2 WHITE AND THE OTHER FOR BROWN, BLACK, BLUE AND GREEN YELLOW LEADS) LENGTH OF 1160 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNNECTOR 6.35 MM
ECOFIT 4GDFU65 200X200L, BASED ON F21-A2, 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES – 2 WHITE AND THE OTHER FOR BROWN, BLACK, BLUE AND GREEN YELLOW LEADS) LENGTH OF 1160 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNNECTOR 6.35 MM
ECOFIT 4GDFU65 180X180L, BASED ON R10-05 BUT IN 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS),BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES WHITE – 2 LEADS AND THE OTHER ONE BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 1694 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35 MM
ECOFIT 4GDFU65 180X180L, BASED ON R10-05 BUT IN 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS),BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES WHITE – 2 LEADS AND THE OTHER ONE BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 1694 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35 MM
ECOFIT 4GDSU35 160X160L, BASED ON F21-A0 115VAC, 60 HZ., CLASS F-UL, WITH A SECOND SPEED BY WINGING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WHITE – 2 LEADS AND THE OTHER ONE FOR BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 2094 ±20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35M.
ECOFIT 4GDSU35 160X160L, BASED ON F21-A0 115VAC, 60 HZ., CLASS F-UL, WITH A SECOND SPEED BY WINGING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WHITE – 2 LEADS AND THE OTHER ONE FOR BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 2094 ±20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35M.