E66-71664

E66-71664
Image Product Brand Fan Type Motor Type Special Class Size Voltage Phase Freq. (Hz) CFM* Max. Air DB A More
E66-71664 E66-71664 Rosenberg Axial EC 710 230 3 60 9437 83

Rosenberg EC Axial Fan, AKFG 710-K.6IF Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 9437 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white (also available in white) with black painted finger guard.

Contact Rosenberg USA for more details.

E66-71664 E66-71664 Rosenberg Axial EC 710 460 3 60 11256 85

Rosenberg EC Axial Fan, AKFG 710-K.6IF Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 11,256 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white (also available black) with black painted finger guard.

Contact Rosenberg USA for more details.

E66-71665 E66-71665 Rosenberg Axial EC 710 230 3 60 8835 82

Rosenberg EC Axial Fan, AKFG 710-K.6FF Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 8835 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-71665 E66-71665 Rosenberg Axial EC 710 460 3 60 9991 82

Rosenberg EC Axial Fan, AKFG 710-K.6FF Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 9991 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-71667 E66-71667 Rosenberg Axial EC 710 230 3 60 9437 83

Rosenberg EC Axial Fan, AKFG 710-K.6IF Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 9437 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted black (white also available) with black painted finger guard.

Contact Rosenberg USA for more details.

E66-71667 E66-71667 Rosenberg Axial EC 710 460 3 60 11256 85

Rosenberg EC Axial Fan, AKFG 710-K.6IF Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 11,256 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted black (also available white) with black painted finger guard.

Contact Rosenberg USA for more details.

E66-80669 E66-80669 Rosenberg Axial EC 800 230 3 60 12488 81

Rosenberg EC Axial Fan, AKFG 800-K.6IF Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 12,488 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-80669 E66-80669 Rosenberg Axial EC 800 460 3 60 11157 83

Rosenberg EC Axial Fan, AKFG 800-K.6IF Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 11,157 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-80670 E66-80670 Rosenberg Axial EC 800 230 3 60 11237 79

Rosenberg EC Axial Fan, AKFG 800-K.6FF Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 11,237 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-80670 E66-80670 Rosenberg Axial EC 800 460 3 60 11207 79

Rosenberg EC Axial Fan, AKFG 800-K.6FF Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 11,207 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-80671 E66-80671 Rosenberg Axial EC 800 230 3 60 10784 80

Rosenberg EC Axial Fan, AKFG 800-K.6NA Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 10,784 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-80671 E66-80671 Rosenberg Axial EC 800 460 3 60 11766 84

Rosenberg EC Axial Fan, AKFG 800-K.6NA Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 11,766 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-90665 E66-90665 Rosenberg Axial EC 900 230 3 60 13776 82

Rosenberg EC Axial Fan, AKFG 900-K.6NA Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 13,776 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-90665 E66-90665 Rosenberg Axial EC 900 460 3 60 16674 85

Rosenberg EC Axial Fan, AKFG 900-K.6NA Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 16,674 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-90667 E66-90667 Rosenberg Axial EC 900 230 3 60 10425 82

Rosenberg EC Axial Fan, AKFG 900-G.6NA Gen3, Input Voltage 200-240 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 10,425 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E66-90667 E66-90667 Rosenberg Axial EC 900 460 3 60 13315 83

Rosenberg EC Axial Fan, AKFG 900-G.6NA Gen3, Input Voltage 380-480 Volt, 3-Phase, 50-60 Hz. Ip54 and UL-R Motor Class F. Max airflow 13,315 CFM. Operating Temperature -40°C To +60°C, Integrated Terminal Box. Shroud Mounting Plate painted white with black painted finger guard.

Contact Rosenberg USA for more details.

E67-45008 E67-45008 Rosenberg Axial AC 450 230 60 4000
E67-45051 E67-45051 Rosenberg Axial AC 450 230 60 4000

ROSENBERG AKSD 450-4N, A4, 230VD/460Y, 60 HZ, IP54

Contact Rosenberg USA for more details.

 

E67-50056 E67-50056 Rosenberg Axial AC 500 460 60 3850

ROSENBERG AKSD 500-4-4K, A6 , IP 54, 460VD/Y, 3 PH, 60 HZ., 3850 CFM AT .52″SP, CONSTRUCTION TYPE 6, UL

Contact Rosenberg USA for more details.

 

E67-50057 E67-50057 Rosenberg Axial AC 500 230-460 3 60 5800 84

AKSD 500-mm / 19.5” diameter: up to 5,800 cfm at free air. AC axial fans, 50-60 Hz, with profiled aluminum sickle blades, complete with shroud and finger guards for condenser applications. Airflow & sound power values shown are at full speed: 460-V & 60 Hz.

Contact Rosenberg USA for more details.

E67-50065 E67-50065 Rosenberg Axial AC 500 230-460 3 60 3850

ROSENBERG AKSD 500-4K, A4, 230 VOLT DELTA / 460 VOLT STAR, 60 HZ, 3PH, UL, IP54, asynchronous external rotor motor, sickle-shaped impellers, terminal box design, protection class IP54, thermal class F

Contact Rosenberg USA for more details.

 

E67-50074 E67-50074 Rosenberg Axial AC 500 460 60 3850

ROSENBERG AKSD 500-4K, A4, 575VY, 60 HZ, IP54

Contact Rosenberg USA for more details.

 

E67-50200 E67-50200 Rosenberg Axial AC 500 230-460 3 60 5000 72

ROSENBERG AKFD 500-4G.5HA condenser fan, A3 construction, 500-mm / 19.5” diameter; 230VD/460VY @ 60 HZ., 230VD/400VY @ 50 HZ., AIRFLOW 5000 CFM @ free air, UL-R MOTOR

Contact Rosenberg USA for more details.

E68-56216 E68-56216 Rosenberg Axial AC 560 230-460 3 60 8400 84

AKFD 560-mm / 21” diameter: up to 8,400 cfm at free air. AC axial fan, 50-60 Hz, with profiled aluminum sickle blades, complete with shroud and finger guards for condenser applications. Airflow & sound power values shown are at full speed: 460-V & 60 Hz.

Contact Rosenberg USA for more details.

E68-56218 E68-56218 Rosenberg Axial AC 560 230-460 3 60 9000 84

ErP-Ready Rosenberg AKFD 560-4N.6HF, A6, 230VD/460VY, 60 HZ, “V”, IP54, PLATE PAINTED RAL9010

Contact Rosenberg USA for more details.

E68-63258 E68-63258 Rosenberg Axial AC 630 230-460 3 60 10500 83

AKFD 630-mm / 24” diameter: up to 10,500 cfm at free air. AC axial fan, 50-60 Hz, with profiled aluminum sickle blades, complete with shroud and finger guards for condenser applications. Airflow & sound power values shown are at full speed: 460-V & 60 Hz.

Contact Rosenberg USA for more details.

E68-66700 E68-66700 Rosenberg Axial AC 665 230-460 3 60 9200 75

AKFD 665-mm / 26” diameter condenser fan: input power 230VD / 460VY, three-phase, 50-60 Hz; 9200 cfm @ free air, 6,000 cfm @ 0.6”; sound power 75 dB(A)

Contact Rosenberg USA for more details.

E68-76261 E68-76261 Rosenberg Axial AC 760 230-460 3 60 12800 83

AKFD 760-mm / 30” diameter: input power 230VD / 460VY, three-phase, 50-60 Hz; 12800 cfm @ free air; 8,000 cfm @ 0.8”; sound power 83 dB(A)

Contact Rosenberg USA for more details.

E68-80277 E68-80277 Rosenberg Axial AC 800 230-460 3 60 14000 82

ErP-Ready Rosenberg AKFD 800-6G.6LA, A4, AC, 230VD/460VY, 60 HZ., 3 PH, UL-R, DIR V,(LOW HEIGHT GRILL WITH HORIZONTAL MOUNTING BRACKETS)

Contact Rosenberg USA for more details.

E68-80287 E68-80287 Rosenberg Axial AC 800 230-460 3 60 15900 80

AKFD 800-mm / 31” diameter: up to 14,500 cfm (G-model) or 15,900 cfm (K-model) @ free air. AC axial fan, 50-60 Hz, with profiled aluminum sickle blades, complete with shroud and finger guards for condenser applications. Airflow & sound power values shown are at full speed: 460-V & 60 Hz.

Contact Rosenberg USA for more details.

E90-31532 E90-31532 Rosenberg Axial AC 315 230-460 60 1700

ROSENBERG DQ 315-4, 230VD/460VY, 60 HZ, AXIAL FAN WITH 430MM SQUARE WALL PLATE, WHITE, AIRFLOW DIRECTION A

Contact Rosenberg USA for more details.

 

E90-31539 E90-31539 Rosenberg Axial AC 315 230 60 2750

ROSENBERG DQ 315-2KS, IP54, 208VD, 60 HZ, 430MM SQUARE WALL PLATE

Contact Rosenberg USA for more details.

 

E90-45037 E90-45037 Rosenberg Axial AC 450 230-460 60 4000

ROSENBERG DQ 450-4KS, 230VD/460VY, 60 HZ, IP54, AXIAL FAN WITH 575MM WHITE SQUARE WALL PLATE, AIRFLOW DIRECTION A

Contact Rosenberg USA for more details.

 

F21-A0 F21-A0 Ecofit Blowers AC 200 115 60 507 56

ECOFIT 4GDSU35 160X160L, BASED ON F21-A0 115VAC, 60 HZ., CLASS F-UL, WITH A SECOND SPEED BY WINGING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WHITE – 2 LEADS AND THE OTHER ONE FOR BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 2094 ±20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35M.

Contact Rosenberg USA for more details.

 

F21-A1 F21-A1 Ecofit Blowers AC 262 115 60 801 62

ECOFIT 4GDFU65 180X180L, BASED ON R10-05 BUT IN 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS),BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES WHITE – 2 LEADS AND THE OTHER ONE BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 1694 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35 MM

Contact Rosenberg USA for more details.

 

F21-A2 F21-A2 Ecofit Blowers AC 0 115 60 737

ECOFIT 4GDFU65 200X200L, BASED ON F21-A2, 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES – 2 WHITE AND THE OTHER FOR BROWN, BLACK, BLUE AND GREEN YELLOW LEADS) LENGTH OF 1160 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNNECTOR 6.35 MM

Contact Rosenberg USA for more details.

 

G01-A5 G01-A5 Ecofit Backward Curved AC 220 115 60 357 52

ECOFIT 4RREU15 220X45R, UL VERSION, 115V, 60 HZ., 1 PH, 280 CFM@0.2″SP.

Contact Rosenberg USA for more details.

 

G28-A0 G28-A0 Ecofit Blowers AC 180 115 1 60 573 57

ECOFIT 4GDFU65180X180L, BASED ON R10-05, 115 VOLT, UL, 1 PHASE

Contact Rosenberg USA for more details.

 

H06-A1 H06-A1 Ecofit Backward Curved AC 250 115 60 671 66

ECOFIT 4RREU35 250X80R, 115VAC, 50/60 HZ., 1 PH

Contact Rosenberg USA for more details.

 

H07-A0 H07-A0 Ecofit Blowers AC 180 230 60 217 57

ECOFIT 2GDSU25 120X126L DOUBLE INLET BLOWER

Contact Rosenberg USA for more details.

 

H31-A2 H31-A2 Ecofit Backward Curved AC 250 115 60 1010 77

Ecofit 2RREu45 250x56R backward curved fan with galvanized steel impeller. Class F, IP44, UL approved motor, ball bearing.

Contact Rosenberg USA for more details.

H35-A4 H35-A4 Ecofit Backward Curved AC 180 115 60 329 62

ECOFIT 2RREU15 180X35R, BASED ON E14-B3, C=68MM, 115V, 50/60 HZ, IP55

Contact Rosenberg USA for more details.

 

I07-A6 I07-A6 Ecofit Backward Curved AC 225 230 60 753 67
I24-A4 I24-A4 Ecofit Backward Curved AC 280 230 60 1077 77

ECOFIT 2RRE45 280X40R, 230 V, 50/60 HZ., BASED ON Z19-07 BUT WITH A CATAPHORESIS ON THE ROTOR, ROTOR PAINTED INSIDE. VARNISH ON WINDING CONNECTION, SEALED BALL BEARINGS

Contact Rosenberg USA for more details.

 

I50-A1 I50-A1 Ecofit Backward Curved AC 220 230 60 594 65

ECOFIT 2RREU25 220X45R, 230V, 1 PH, 60 HZ

Contact Rosenberg USA for more details.

 

J12-A8 J12-A8 Ecofit Blowers AC 133 230 1 60 288

J12-A8: 2GDSu25 133x190R (133-mm diameter impeller / 230-Volt) 3-speed model, 1-phase, ERP 2015 compliant

Contact Rosenberg USA for more details.

J40-A2 J40-A2 Ecofit Blowers AC 120 115 1 60 235

J40-A2: 2GDSu15 120x126L (120-mm diameter impeller, 115-Volt, 1-phase, 3-speed model, ERP 2015 compliant)

Contact Rosenberg USA for more details.

J50-A4 J50-A4 Ecofit Blowers AC 120 115 60 194 54

ECOFIT 2GDSU15 120X126L115VAC, 50/60 HZM, SPECIAL AIR OUTPUT FOR HEAT SINK APPLICATIONS ACCORING TO ECOFIT DRAWING PDR10-140-0, CAPACITOR ASSEMBLY ON THE AIR OUTPUT, WAGO CONNECTOR ASSEMBLY ON THE SCROLL AND FINGERGUARDS.

Contact Rosenberg USA for more details.

K13-A3 K13-A3 Ecofit Backward Curved AC 250 115 60 853 77

ECOFIT 2RREU45 250X56R, 115VAC, 50/60 HZ, 1 PH, DROP-IN, UL-R, 894 CFM AT FREE AIR, 3 SPEED (LOW 50%, MEDIUM 75%, HIGH 100 %)

Contact Rosenberg USA for more details.

 

K16-A1 K16-A1 Ecofit Blowers AC 146 460 3 60 426 65

ECOFIT 2GDFUT65 146X180L DOUBLE INLET CENTRIFUGAL FAN BASED ON C03-A3, 400 TO 460V, 3 PH, 60 HZ.M BUT WITH PAINTED ROTOR. INDIVIDUALLY PACKED.

Contact Rosenberg USA for more details.

K34-A2 K34-A2 Ecofit Blowers AC 133 115 60 338 54

ECOFIT 2GDSU35 133X190R, 3 SPEED. HIGH SPEED: 100V, 2.8 A, MEDIUM SPEED: 80V, 2.2 A, LOW SPEED: 70V, 2 A

Contact Rosenberg USA for more details.

M10-A2 M10-A2 Ecofit Blowers EC 146 230 1 60 500 56

GDSuG9 146x188R (PN # M10-A2), EC, 230-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

Contact Rosenberg USA for more details.

M14-A2 M14-A2 Ecofit Blowers AC 180 115 1 60 795 57

ECOFIT 4GDFU65 180X180L, 115-Volt, 1-phase, 4-pole motor, 270-Watt power consumption and 795 cfm @ free air, up to 1.4” of water pressure (no air), sound pressure 57 dB(A), non-flange scroll housing

Contact Rosenberg USA for more details.

M15-A0 M15-A0 Ecofit Blowers EC 160 115 1 60 280

GREuG9 160X62R (PN # M15-A0), EC, 120-Volt, 1-phase, Constant Airflow, airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M21-A1 M21-A1 Ecofit Blowers EC 160 230 1 60 364

GREuG9 160x62R (PN # M21-A1), EC, 230-Volt, 1-phase, Standard Airflow-Pressure; airflow up to 364 cfm or up to 2.8” of static pressure ”

Contact Rosenberg USA for more details.

M22-A8 M22-A8 Ecofit Blowers EC 146 230 1 60 500 58

GDSuG9 146x188R (PN # M22-A8), EC, 230-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

Contact Rosenberg USA for more details.

M27-A4 M27-A4 Ecofit Blowers EC 146 230 1 60 565 59

GDSuG9 146x188R (PN # M27-A4), EC, 230-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

Contact Rosenberg USA for more details.

M36-A4 M36-A4 Ecofit Blowers EC 160 230 1 60 280

GREuG9 160x62R (PN # M36-A4), 230-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M36-A5 M36-A5 Ecofit Blowers EC 160 230 1 60 280

GREuG9 160x62R (PN # M36-A5), 230-Volt, 1-phase, Constant Airflow; airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M36-A7 M36-A7 Ecofit Blowers EC 160 115 1 60 280

GREuG9 160x62R (PN # M36-A7), 120-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure

Contact Rosenberg USA for more details.

M41-A0 M41-A0 Ecofit Blowers AC 133 115 1 60 313

M41-A0: 2GDSu35 133x190R (133-mm diameter impeller / 115-Volt) – Salt Spray, 3-Speed, single phase, ErP 2015 compliant

Contact Rosenberg USA for more details.

N11-A2 N11-A2 Ecofit Blowers EC 146 115 1 60 565 59

GDSuG9 146x188R (PN # N11-A2), EC, 120-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

Contact Rosenberg USA for more details.

N17-A5 N17-A5 Ecofit Blowers EC 146 115 1 60 500 58

GDSuG9 146x188R (PN # N17-A5), EC, 120-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

Contact Rosenberg USA for more details.

N23-A8 N23-A8 Ecofit Blowers EC 146 115 1 60 500 58

GDSuG9 146x188R (PN # N23-A8), EC, 120-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

Contact Rosenberg USA for more details.

N24-B2 N24-B2 Ecofit Blowers AC 133 115 1 60 300

N24-B2: 2GDSu25 133x190R (133-mm diameter impeller, 3-speed, 115-Volt, 1-phase, ERP 2015)

Contact Rosenberg USA for more details.

N43-28001 N43-28001 Rosenberg Backward Curved EC 280 230 1 60 1000 77

Rosenberg model GKHM 280-CIE.065.4EA IE HP fan module with high-efficiency 120-V / 1-Phase 400 Watt EC motor and super quiet impeller made of glass fiber reinforced polyamide. 1000 cfm @ 2”

Contact Rosenberg USA for more details.

N43-28003 N43-28003 Rosenberg Backward Curved EC 280 115 1 60 1000 76

Rosenberg model GKHM 280-CIE.065.4EA IE HP fan module with high-efficiency 120-V / 1-Phase 400 Watt EC motor and super quiet impeller made of glass fiber reinforced polyamide. 1000 cfm @ 1.9”

Contact Rosenberg USA for more details.

N52-35509 N52-35509 Rosenberg Backward Curved AC 355 115 1 60 2020 78

1-phase EKHR 355-4SH.127.5DFwith glass fiber reinforced polyamide impeller

Contact Rosenberg USA for more details.

N61-63010 N61-63010 Rosenberg Backward Curved AC 630 230-460 3 60 4525 84

3-phase DKHR 630-6SH.224.6LA with backward curved aluminum impeller

Contact Rosenberg USA for more details.

N61-71045 N61-71045 Rosenberg Backward Curved AC 710 230-460 3 60 6195
N63-22509 N63-22509 Rosenberg Backward Curved AC 225 230 1 60 905
N63-22511 N63-22511 Rosenberg Backward Curved AC 225 230-460 3 60 905
N63-22555 N63-22555 Rosenberg Backward Curved AC 225 230 1 60 873
N63-22556 N63-22556 Rosenberg Backward Curved AC 225 115 1 60 873
N63-22557 N63-22557 Rosenberg Backward Curved AC 225 230 1 60 873
N63-25019 N63-25019 Rosenberg Backward Curved AC 250 230-460 3 60 1100
N63-25061 N63-25061 Rosenberg Backward Curved AC 250 115 1 60 1036
N63-25062 N63-25062 Rosenberg Backward Curved AC 250 230 1 60 1036
N63-28034 N63-28034 Rosenberg Backward Curved AC 280 230-460 3 60 1800

DKHR 280-2SW.087.5FA: 11” diameter / 3-phase / 230/460-Volt model

Contact Rosenberg USA for more details.

N63-28039 N63-28039 Rosenberg Backward Curved AC 280 460 3 60 1441
N63-28055 N63-28055 Rosenberg Backward Curved AC 280 230 1 60 1611
N63-28057 N63-28057 Rosenberg Backward Curved AC 280 115 1 60 1600
N63-31055 N63-31055 Rosenberg Backward Curved AC 310 115 1 60 1290

310-mm (12” diameter) / 1-phase EKHR 310-4SH.100.4EC with glass fiber reinforced polyamide impeller

Contact Rosenberg USA for more details.

N63-31064 N63-31064 Rosenberg Backward Curved AC 310 230 1 60 1290

310-mm (12” diameter) / 1-phase EKHR 310-4SH.100.4EC with glass fiber reinforced polyamide impeller

Contact Rosenberg USA for more details.

N63-31523 N63-31523 Rosenberg Backward Curved AC 315 230-460 3 60 2765
N63-31541 N63-31541 Rosenberg Backward Curved AC 315 230-460 3 60 2190
N63-35523 N63-35523 Rosenberg Backward Curved AC 355 230 1 60 2574
N63-35559 N63-35559 Rosenberg Backward Curved AC 355 115 1 60 2052
N63-35582 N63-35582 Rosenberg Backward Curved AC 355 230-460 3 60 2240
N63-40017 N63-40017 Rosenberg Backward Curved AC 400 230-460 3 60 3400 83

3-phase DKHR 400-4SW.123.6FA: N63-40017 with aluminum impeller

Contact Rosenberg USA for more details.

N63-40058 N63-40058 Rosenberg Backward Curved AC 400 230 1 60 2960
N63-45018 N63-45018 Rosenberg Backward Curved AC 450 230-460 3 60 5000
N63-45022 N63-45022 Rosenberg Backward Curved AC 450 575 3 60 4865
N63-50024 N63-50024 Rosenberg Backward Curved AC 500 230-460 3 60 7100
N63-56044 N63-56044 Rosenberg Backward Curved AC 560 575 3 60 8800
N63-56050 N63-56050 Rosenberg Backward Curved AC 560 230-460 3 60 9100
N63-63019 N63-63019 Rosenberg Backward Curved AC 630 460 3 60 9300

ROSENBERG DKHR 630-6SW.195.7KF 8-blade impeller constructed from sea-waterproof aluminum. Quality class G 2.5, DIN/ISO 1940. Maintenance free ball bearings. Standard external rotor motors. Protection class IP 44/54. CE, UL and RoHS approved.

Contact Rosenberg USA for more details.

N86-28003 N86-28003 Rosenberg Backward Curved EC 280 115 1 60 1500 81

ROSENBERG EC, GKHR 280-CIW.087.4EA, 1 PH, 100-130V, 50/60 HZ

Contact Rosenberg USA for more details.

 

N86-31552 N86-31552 Rosenberg Backward Curved EC 315 230 1 60 1760 81

ROSENBERG EC, GKHR 315-CIW.098.4EA, 1PH, 200/277V, 50/60 HZ.

Contact Rosenberg USA for more details.

 

N86-31555 N86-31555 Rosenberg Backward Curved EC 315 115 1 60 1700 80

ROSENBERG EC, GKHR 315-CIW.098.4EA. 1 PH, 100-130V, 50/60 HZ

Contact Rosenberg USA for more details.

 

Go to Top