Item | Brand | Fan Type | Motor Type | Special Class | Size | Voltage | Phase | Freq. (Hz) | CFM* Max. Air | DB A | More | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rosenberg | Backward Curved | AC | – | 225 | 230 | 1 | 60 | 873 | – | > V More | ||
ROSENBERG EKHR 225-2SW.070.4FF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 250 | 230-460 | 3 | 60 | 1100 | – | > V More | ||
ROSENBERG DKHR 250-2SW.060.4FF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 250 | 115 | 1 | 60 | 1036 | – | > V More | ||
ROSENBERG EKHR 250-2SW.060.4FF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 250 | 230 | 1 | 60 | 1036 | – | > V More | ||
ROSENBERG EKHR 250-2SW.060.4FF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 280 | 230-460 | 3 | 60 | 1800 | – | > V More | ||
DKHR 280-2SW.087.5FA: 11” diameter / 3-phase / 230/460-Volt model Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 280 | 460 | 3 | 60 | 1441 | – | > V More | ||
ROSENBERG DKHR 280-2SW.060.5FA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 280 | 230 | 1 | 60 | 1611 | – | > V More | ||
ROSENBERG EKHR 280-2SW.087.5HA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 280 | 115 | 1 | 60 | 1600 | – | > V More | ||
ROSENBERG EKHR 280-2SW.087.5HA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 310 | 115 | 1 | 60 | 1290 | – | > V More | ||
310-mm (12” diameter) / 1-phase EKHR 310-4SH.100.4EC with glass fiber reinforced polyamide impeller Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 310 | 230 | 1 | 60 | 1290 | – | > V More | ||
310-mm (12” diameter) / 1-phase EKHR 310-4SH.100.4EC with glass fiber reinforced polyamide impeller Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 315 | 230-460 | 3 | 60 | 2765 | – | > V More | ||
ROSENBERG DKHR 315-2SW.098.6FA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 315 | 230-460 | 3 | 60 | 2190 | – | > V More | ||
ROSENBERG DKHR 315-2SW.070.5HA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 355 | 230 | 1 | 60 | 2574 | – | > V More | ||
ROSENBERG DKHR 355-2SW.078.6HF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 355 | 115 | 1 | 60 | 2052 | – | > V More | ||
ROSENBERG EKHR 355-4SW.110.5FA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 355 | 230-460 | 3 | 60 | 2240 | – | > V More | ||
ROSENBERG DKHR 355-4SW.110.5DF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 400 | 230 | 1 | 60 | 2960 | – | > V More | ||
ROSENBERG EKHR 400-4SW.123.5HA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 450 | 230-460 | 3 | 60 | 5000 | – | > V More | ||
ROSENBERG DKHR 450-4SW.138.6HF Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 560 | 230-460 | 3 | 60 | 9100 | – | > V More | ||
ROSENBERG DKHR 560-4SW.155.7NA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 630 | 460 | 3 | 60 | 9300 | – | > V More | ||
ROSENBERG DKHR 630-6SW.195.7KF 8-blade impeller constructed from sea-waterproof aluminum. Quality class G 2.5, DIN/ISO 1940. Maintenance free ball bearings. Standard external rotor motors. Protection class IP 44/54. CE, UL and RoHS approved. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 280 | 115 | 1 | 60 | 1500 | 81 | > V More | ||
ROSENBERG EC, GKHR 280-CIW.087.4EA, 1 PH, 100-130V, 50/60 HZ Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 450 | 575 | 3 | 60 | 4865 | – | > V More | ||
ROSENBERG DKHR 450-4SW.138.6FA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 500 | 230-460 | 3 | 60 | 7100 | – | > V More | ||
ROSENBERG DKHR 500-4SW.155.6LA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | AC | – | 560 | 575 | 3 | 60 | 8800 | – | > V More | ||
ROSENBERG DKHR 560-4SW.174.7NA Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 315 | 230 | 1 | 60 | 1760 | 81 | > V More | ||
ROSENBERG EC, GKHR 315-CIW.098.4EA, 1PH, 200/277V, 50/60 HZ. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 315 | 115 | 1 | 60 | 1700 | 80 | > V More | ||
ROSENBERG EC, GKHR 315-CIW.098.4EA. 1 PH, 100-130V, 50/60 HZ Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 355 | 230 | 3 | 60 | 2960 | 88 | > V More | ||
ROSENBERG EC, GKHR 355-CIW.110.5FA, 3 PH, 200-240V, 50/60 HZ Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 400 | 230 | 1 | 60 | 2445 | 78 | > V More | ||
ROSENBERG EC, GKHR 400-CIW.123.4FF, 1 PH, 200-277V, 50/60 HZ Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 400 | 230 | 3 | 60 | 3450 | 87 | > V More | ||
ROSENBERG EC, GKHR 400-CIW.123.5HF, 3 PH, 200-240V, 50/60 HZ. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 400 | 460 | 3 | 60 | 5550 | 96 | > V More | ||
ROSENBERG EC, GKHR 400-CIA.125.6FF, 3 PH. 380/480V, 50/60 HZ, 3 PH, IP54 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 450 | 460 | 3 | 60 | 6080 | 95 | > V More | ||
ROSENBERG EC, GKHR 450-CIW.138.6FF, 3 PH, 380/480V, 50/60 HZ Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 450 | 230 | 3 | 60 | 6080 | 95 | > V More | ||
ROSENBERG EC, GKHR 450-CIW.138.6FF, 200-240VAC, 3 PH, 50/60 HZ Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 500 | 460 | 3 | 60 | 6610 | 92 | > V More | ||
ROSENBERG EC, GKHR 500-CIW.155.6IF, 3PH, 380/480V, 50/60 HZ. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 500 | 230 | 1 | 60 | 4950 | 84 | > V More | ||
ROSENBERG EC, GKHR 500-CIW.155.5HF, 200-277V, 50/60 HZ., 1 PH, IP54 Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 280 | 460 | 3 | 60 | 2200 | 94 | > V More | ||
ROSENBERG EC MODULE, GKHM 280-CIW.087.5FA, 3 PH, 380-480V, 50/60 HZ, IP54, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 450 | 230 | 1 | 60 | 2298 | 78 | > V More | ||
ROSENBERG EC, GKHR 450-CIW.098.4FF, 1 PH, 230V, 50/60 HZ Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 280 | 230 | 1 | 60 | 1750 | 80 | > V More | ||
Rosenberg EC fan with B-Wheel impeller, GKH_ 280-CIB.090.4EA-IE, available as fan module or motorized impeller Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 315 | 460 | 3 | 60 | 2400 | 92 | > V More | ||
ROSENBERG EC MODULE, GKHM 315-CIW.080.5FA 3 PH 380-480V, 50/60HZ, IP54, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 315 | 115 | 1 | 60 | – | – | > V More | ||
ROSENBERG EC MODULE, GKHM 315-CIW.070.5FA, IE-061, 1PH/ 100-130V, 50/60 HZ, IP54, EC RADIAL FAN, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 355 | 230 | 3 | 60 | 3000 | 86 | > V More | ||
ROSENBERG EC MODULE, GKHM 355-CIW.110.5FA, 3 PH, 200-240V, 50/60 HZ, IP54, WITH PRESSURE TAB INLET CONE Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 355 | 460 | 3 | 50 | 3500 | 89 | > V More | ||
Rosenberg EC fan with B-Wheel impeller, GKHM 355-CIB.112.5HF-IE, available as fan module or motorized impeller Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 450 | 460 | 3 | 60 | 5580 | 84 | > V More | ||
ROSENBERG EC MODULE, GKHM 450-CIW.138.6FF, 3PH, 380/480V, 50/60 HZ., IP54, UL-R, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 500 | 230 | 3 | 60 | 6610 | 92 | > V More | ||
ROSENBERG EC MODULE, GKHM 500-CIW.155.6IF, 3PH, 200/240V, 50/60 HZ., IP54, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 500 | 230 | 3 | 60 | 6610 | 92 | > V More | ||
ROSENBERG EC MODULE, GKHM 500-CIW.155.6IF, 3PH, 200/240V, 50/60 HZ., IP54, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 500 | 460 | 3 | 60 | 6880 | 93 | > V More | ||
ROSENBERG EC MODULE, GKHM 500-CIW.155.6IF-004, 3 PH, 380/480V, 50/60 HZ, IP54, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 560 | 230 | 3 | 60 | 8500 | 92 | > V More | ||
ROSENBERG EC MODULE, GKHM 560-CIW.174.6IF IE-VO2, 3 PH, 200-240V, 50/60 HZ, IP54, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 560 | 230 | 3 | 60 | 8850 | 90 | > V More | ||
ROSENBERG EC MODULE, GKHM 560-CIA.180.6IF, IE, 200-240V, 3 PHA, 50/60 HZ, IP54, ALUMINUM RING, INCLUDES INLET CONE WITH PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Rosenberg | Backward Curved | EC | – | 630 | 460 | 3 | 60 | 10990 | 89 | > V More | ||
ROSENBERG EC, GKHM 630-CIA.200.6NA IE-VO3, 3PH, 380-480V, 50/60 HZ, IP54, INLET CONE WITHOUT PRESSURE MEASURING TABS Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Ecofit | Backward Curved | AC | – | 250 | 230 | 1 | 60 | 1038 | 71 | > V More | ||
Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Ecofit | Backward Curved | AC | – | 250 | 115 | 1 | 60 | 1059 | 71 | > V More | ||
Q13-A1, 2RREu45 250x50R, E-Impeller, 1-phase, 115-Volt, 243 Watts, Max airflow at free air 1059 CFM - airflow at 1.2” 760 CFM, temperature range -40 to +70°C. ERP 2015 compliant. Contact Rosenberg USA for more details. | Get More Information: | ||||||||||||
| Ecofit | Backward Curved | AC | – | 250 | 230 | 1 | 60 | 1162 | – | > V More | ||
Q13-A0, 2RREu45 250x50R, E-Impeller,1-phase, 230-Volt, Max airflow at free air 1162 CFM, temperature range -4 to +140°f. ERP 2015 compliant. Contact Rosenberg USA for more details. | Get More Information: |