S03-A2 Rev. a

Rosenberg, Ecofit and ETRI Fans

  • ECOFIT double inlet blower, 2GDSU15 120X126L, 120V, 1-phase 50-60 HZ. IP44 and UL-R motor class F, with sealed bearings, wired-in thermo-contact, operating temperature -40°C TO +70°C. galvanized steel scroll housing with four mounting brackets on the air exhaust, 800-mm connection cable, ERP 2015.
  • Ecofit EC GREUG9 160X62, 115V, 50/60 Hz, single phase, UL-R motor, standard airflow pressure
  • Ecofit EC double inlet blower with EC motor, GDSUG9 146X188R, 120V, 1 PH, 50/60 Hz, UL-R motor, black painted scroll housing with flange, standard
  • Ecofit Z03-01: 4GDSu35 146x180L (146-mm impeller diameter, 115-Volt, 1-phase, 3-speed model, ERP 2015 compliant)
  • ECOFIT 2GDS35 133X190L, 230VOLT, 50/60 HZ., 335 CFM AT FREE AIR OPERATING AT 60 HZ., SEE ALSO L23-A6
  • ECOFIT 2GREU25 140X59R, 115VAC, 50/60 HZ. SINGLE INLET
  • Q37-B2 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Constant Airflow Model; CE-only, ERP 2015 compliant, 510 CFM @ 1.8", 824 CFM @ free air
  • Q37-B3 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Constant Pressure model; CE-only, ERP 2015 compliant, 500 CFM @ 1.7", 1010 CFM @ free air

  • Q37-B1 GDSV8 Double Inlet Centrifugal Fan, 180x180L; 1-phase, 230-Volt; Standard Airflow/Pressure model; CE-only, ERP 2015 compliant, 557 CFM @ 2.2", 1015 CFM @ free air

  • N24-B2: 2GDSu25 133x190R (133-mm diameter impeller, 3-speed, 115-Volt, 1-phase, ERP 2015)
  • GDSuG9 146x188R (PN # N23-A8), EC, 120-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

  • GDSuG9 146x188R (PN # N17-A5), EC, 120-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

  • GDSuG9 146x188R (PN # N11-A2), EC, 120-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

  • M41-A0: 2GDSu35 133x190R (133-mm diameter impeller / 115-Volt) – Salt Spray, 3-Speed, single phase, ErP 2015 compliant
  • GREuG9 160x62R (PN # M36-A7), 120-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure
  • GREuG9 160x62R (PN # M36-A5), 230-Volt, 1-phase, Constant Airflow; airflow up to 280 cfm or up to 2.7” of static pressure
  • GDSuG9 146x188R (PN # M22-A8), EC, 230-Volt, 1-phase, Constant Pressure blower with forward curved impeller, up to 500 cfm at free air, up to 300 cfm @ 1.4”

  • GDSuG9 146x188R (PN # M27-A4), EC, 230-Volt, 1-phase, Standard Airflow-Pressure blower with forward curved impeller, up to 565 cfm at free air

  • GREuG9 160x62R (PN # M36-A4), 230-Volt, 1-phase, Constant Pressure; airflow up to 280 cfm or up to 2.7” of static pressure
  • GREuG9 160x62R (PN # M21-A1), EC, 230-Volt, 1-phase, Standard Airflow-Pressure; airflow up to 364 cfm or up to 2.8” of static pressure "
  • GREuG9 160X62R (PN # M15-A0), EC, 120-Volt, 1-phase, Constant Airflow, airflow up to 280 cfm or up to 2.7” of static pressure
  • ECOFIT 4GDFU65 180X180L, 115-Volt, 1-phase, 4-pole motor, 270-Watt power consumption and 795 cfm @ free air, up to 1.4” of water pressure (no air), sound pressure 57 dB(A), non-flange scroll housing
  • GDSuG9 146x188R (PN # M10-A2), EC, 230-Volt, 1-phase, Constant Airflow blower with forward curved impeller, up to 500 cfm at free air

  • ECOFIT 2GDSU35 133X190R, 3 SPEED. HIGH SPEED: 100V, 2.8 A, MEDIUM SPEED: 80V, 2.2 A, LOW SPEED: 70V, 2 A
  • ECOFIT 2GDFUT65 146X180L DOUBLE INLET CENTRIFUGAL FAN BASED ON C03-A3, 400 TO 460V, 3 PH, 60 HZ.M BUT WITH PAINTED ROTOR. INDIVIDUALLY PACKED.
  • J12-A8: 2GDSu25 133x190R (133-mm diameter impeller / 230-Volt) 3-speed model, 1-phase, ERP 2015 compliant
  • J40-A2: 2GDSu15 120x126L (120-mm diameter impeller, 115-Volt, 1-phase, 3-speed model, ERP 2015 compliant)

  • ECOFIT 2GDSU15 120X126L115VAC, 50/60 HZM, SPECIAL AIR OUTPUT FOR HEAT SINK APPLICATIONS ACCORING TO ECOFIT DRAWING PDR10-140-0, CAPACITOR ASSEMBLY ON THE AIR OUTPUT, WAGO CONNECTOR ASSEMBLY ON THE SCROLL AND FINGERGUARDS.

  • ECOFIT 2GDSU25 120X126L DOUBLE INLET BLOWER
  • ECOFIT 4GDFU65180X180L, BASED ON R10-05, 115 VOLT, UL, 1 PHASE
  • ECOFIT 4GDFU65 200X200L, BASED ON F21-A2, 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES - 2 WHITE AND THE OTHER FOR BROWN, BLACK, BLUE AND GREEN YELLOW LEADS) LENGTH OF 1160 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNNECTOR 6.35 MM
  • ECOFIT 4GDSU35 160X160L, BASED ON F21-A0 115VAC, 60 HZ., CLASS F-UL, WITH A SECOND SPEED BY WINGING (25% LESS), BUT WITH 2 CABLES (ONE FOR CAPACITOR WHITE - 2 LEADS AND THE OTHER ONE FOR BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 2094 ±20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35M.
  • ECOFIT 4GDFU65 180X180L, BASED ON R10-05 BUT IN 115VAC, 60 HZ., CLASS F-UL WITH SECOND SPEED BY WINDING (25% LESS),BUT WITH 2 CABLES (ONE FOR CAPACITOR WIRES WHITE - 2 LEADS AND THE OTHER ONE BROWN, BLACK, BLUE AND GREEN YELLOW). LENGTH 1694 MM ± 20 MM OUT OF SCROLL, WITH FEMALE TERMINAL 6.35 MM AND WITH CONNECTOR 6.35 MM
  • D50-A2: 2GDSu35 133x126R (133-mm diameter impeller / 115-Volt) 1-Speed Fans with a larger air exhaust flange for Heat Sink cooling
  • ROSENBERG 195-4L.5FA, 195-MM IMPELLER DIAMETER, 230VD/460VY, 60 HZ, WITHOUT MOUNTING RAILS, WITH MOUNTING FLANGES ON THE AIR EXHAUST, UL-R MOTOR (1,400 cfm @ 0.4” of pressure)

  • Rosenberg double-inlet DRAD 200-4B forward curved AC blower; Wheel width 200 mm; 341W x 318D x 400H; 230-460, 3~ , 50/60 Hz; 1,400 cfm @ 0.7”

  • Rosenberg DRAD 240-4L double-width AC forward curved blower; wheel width 240 mm; 378W x 368D x 400H; IP54 Protection; Voltage: 460, 3~, 60 Hz; 2,500 cfm @ 0.8”

  • Rosenberg double-inlet DRAD 251-4L forward curved AC blower; Wheel width 251 mm; body dimensions 378W x 400D x 443H; 230-460, 3~ , 50/60 Hz; 2,500 cfm @ 1”

  • Rosenberg DRAD 279-4 double-width AC forward curved blower; wheel width 279 mm; 378W x 402 x 443H; IP54 Protection; Voltage: 230-460, 3~, 60 Hz; 3,200 cfm @ 1”

  • Rosenberg double-inlet DRAD 281-4 forward curved AC blower; Wheel width 281 mm; body dimensions 378W x 470D x 523H; 230-460, 3~ , 50/60 Hz; 3,300 cfm @ 1.4”

  • Rosenberg DRAD 315-4 double-width AC forward curved blower; wheel width 315 mm; 462W x 536 x 638H; Voltage: 230-460, 3~, 60 Hz; 4,000 cfm @ 2.1”, 5,600 cfm @ 1.15” of pressure

  • ECOFIT 2GDSU25 133X190R, 115V, CLASS F UL
  • ECOFIT 2GDFU65146X180L, BASED ON Z18-26, 115 VOLT, UL, 1 PHASE
  • ECOFIT 2GDSU15 120X126L, 115VAC, 50/60 HZ., 206 CFM AT FREE AIR
Go to Top