Image Product Brand Fan Type Motor Type Special Class Size Voltage Phase Freq. (Hz) CFM* Max. Air DB A More
N86-45700 N86-45700 Rosenberg Backward Curved EC 450 380-480 ~3 60 6300 76

Rosenberg GKHR 450-CII.147.5HF IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 4120 CFM @ 2.44 in WC; 6300 CFM @ free air.

Contact Rosenberg USA for more details.

N86-45701 N86-45701 Rosenberg Backward Curved EC 450 380-480 ~3 60 8829 84

Rosenberg GKHR 450-CII.147.6FF IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5473 CFM @ 4.22 in WC; 8829 CFM @ free air.

Contact Rosenberg USA for more details.

N86-45702 N86-45702 Rosenberg Backward Curved EC 450 380-480 ~3 60 9947 88

Rosenberg GKHR 450-CII.147.6IF IE Gen3+ AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5990 CFM @ 6.11 in WC; 9947 CFM @ free air.

Contact Rosenberg USA for more details.

N86-50303 N86-50303 Rosenberg Backward Curved EC 500 380-480 ~3 60 8534 87

Rosenberg GKHR 500-CIB.160.6IF IE Gen3 AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 4787 CFM @ 4.92 in WC; 8534 CFM @ free air.

Contact Rosenberg USA for more details.

N86-50304 N86-50304 Rosenberg Backward Curved EC 500 380-480 ~3 60 9947 91

Rosenberg GKHR 500-CIB.160.6NA IE Gen3+ AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 6646 CFM @ 5.73 in WC; 9947 CFM @ free air.

Contact Rosenberg USA for more details.

N86-50700 N86-50700 Rosenberg Backward Curved EC 500 380-480 ~3 60 10006 85

Rosenberg GKHR 500-CII.164.6IF IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5384 CFM @ 4.76 in WC; 10006 CFM @ free air.

Contact Rosenberg USA for more details.

N86-50701 N86-50701 Rosenberg Backward Curved EC 500 380-480 ~3 60 11772 89

Rosenberg GKHR 500-CII.164.6NA IE Gen3+ AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 6949 CFM @ 6.03 in WC; 11772 CFM @ free air.

Contact Rosenberg USA for more details.

N86-50702 N86-50702 Rosenberg Backward Curved EC 500 380-480 ~3 60 6769 76

Rosenberg GKHR 500-CII.164.5HF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 4231 CFM @ 2.00 in WC; 6769 CFM @ free air.

Contact Rosenberg USA for more details.

N86-50703 N86-50703 Rosenberg Backward Curved EC 500 380-480 ~3 60 9417 84

Rosenberg GKHR 500-CII.164.6FF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5696 CFM @ 3.80 in WC; 9417 CFM @ free air.

Contact Rosenberg USA for more details.

N86-56700 N86-56700 Rosenberg Backward Curved EC 560 380-480 ~3 60 12831 84

Rosenberg GKHR 560-CII.183.6NA IE Gen3+ AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 8003 CFM @ 4.47 in WC; 12831 CFM @ free air.

Contact Rosenberg USA for more details.

N86-56702 N86-56702 Rosenberg Backward Curved EC 560 380-480 ~3 60 9947 77

Rosenberg GKHR 560-CII.183.6FF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5583 CFM @ 2.97 in WC; 9947 CFM @ free air.

Contact Rosenberg USA for more details.

N86-56703 N86-56703 Rosenberg Backward Curved EC 560 380-480 ~3 60 11301 81

Rosenberg GKHR 560-CII.183.6IF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 6765 CFM @ 3.71 in WC; 11301 CFM @ free air.

Contact Rosenberg USA for more details.

N86-63700 N86-63700 Rosenberg Backward Curved EC 630 380-480 ~3 60 12831 80

Rosenberg GKHR 630-CII.200.6NA IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 7696 CFM @ 3.26 in WC; 12831 CFM @ free air.

Contact Rosenberg USA for more details.

N86-63701 N86-63701 Rosenberg Backward Curved EC 630 380-480 ~3 60 11772 79

Rosenberg GKHR 630-CII.200.6IF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 6615 CFM @ 2.99 in WC; 11772 CFM @ free air.

Contact Rosenberg USA for more details.

N88-28300B N88-28300B Rosenberg Backward Curved EC 280 230 1 60 1750 80

Rosenberg EC fan with B-Wheel impeller, GKH_ 280-CIB.090.4EA-IE, available as fan module or motorized impeller

Rosenberg EC fan with B-Wheel impeller, GKH_ 280-CIB.090.4EA-IE, available as fan module or motorized impeller

Contact Rosenberg USA for more details.

N88-35555 N88-35555 Rosenberg Backward Curved EC 355 460 3 60 2000 88

Rosenberg EC module, GKHM 355-CIW.110.5HF, 3 PH, 380-480V, 50/60 HZ., IP54, with pressure tab inlet cone. Supplied in open loop mode (0-10V). Software for closed loop mode not included.

Rosenberg EC module, GKHM 355-CIW.110.5HF, 3 PH, 380-480V, 50/60 HZ., IP54, with pressure tab inlet cone. Supplied in open loop mode (0-10V). Software for closed loop mode not included.

Contact Rosenberg USA for more details.

N88-35558 N88-35558 Rosenberg Backward Curved EC 355 230 3 60 2005 89

Rosenberg EC module, GKHM 355-CIW.110.5HF, 3PH, 200-240V, 50/60 HZ., IP54, UL-R, includes inlet cone with pressure-measuring tabs. Supplied in open loop mode. Software for closed loop mode not included.

Rosenberg EC module, GKHM 355-CIW.110.5HF, 3PH, 200-240V, 50/60 HZ., IP54, UL-R, includes inlet cone with pressure-measuring tabs. Supplied in open loop mode. Software for closed loop mode not included.

Contact Rosenberg USA for more details.

N88-45316 N88-45316 Rosenberg Backward Curved EC 450 380-480 ~3 60 7122 89

Rosenberg GKHM 450-CIB.140.6IF IE Gen3 AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 4208 CFM @ 5.55 in WC; 7122 CFM @ free air.

Contact Rosenberg USA for more details.

N88-45319 N88-45319 Rosenberg Backward Curved EC 450 380-480 ~3 60 7710 90

Rosenberg GKHM 450-CIB.140.6IF IE Gen3+ AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 4240 CFM @ 6.50 in WC; 7710 CFM @ free air.

Contact Rosenberg USA for more details.

N88-45320 N88-45320 Rosenberg Backward Curved EC 450 380-480 ~3 60 5150 80

Rosenberg GKHM 450-CIB.140.5HF IE Gen3 AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 3191 CFM @ 2.82 in WC; 5150 CFM @ free air.

Contact Rosenberg USA for more details.

N88-45321 N88-45321 Rosenberg Backward Curved EC 450 380-480 ~3 60 7004 89

Rosenberg GKHM 450-CIB.140.6FF IE Gen3 AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 4287 CFM @ 5.33 in WC; 7004 CFM @ free air.

Contact Rosenberg USA for more details.

N88-45322 N88-45322 Rosenberg Backward Curved EC 450 380-480 ~3 60 8181 92

Rosenberg GKHM 450-CIB.140.6NA IE Gen3+ AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 5271 CFM @ 6.31 in WC; 8181 CFM @ free air.

Contact Rosenberg USA for more details.

N88-45604 Gen 3+ N88-45604 Gen 3+ Rosenberg Backward Curved EC 450 230 3 60 4000 85

Rosenberg EC Backward Curved Impeller GKHM 450-CIG.128.6IF IE Gen3+, (PN # N88-45604, 4.1kW, 230-Volt, 3-Phase, 4000 CFM @ 4 inWG.

Rosenberg EC Backward Curved Impeller GKHM 450-CIG.128.6IF IE Gen3+, (PN # N88-45604, 4.1kW, 230-Volt, 3-Phase, 4000 CFM @ 4 inWG.

Contact Rosenberg USA for more details.

N88-45604 Gen 3+ N88-45604 Gen 3+ Rosenberg Backward Curved EC 450 460 3 60 6000 92

Rosenberg EC Backward Curved Impeller, GKHM 450-CIG.128.6IF IE Gen3+, 5.9kW, 460-Volt, 3-Phase, 6000 CFM @ 4 inWG.

Rosenberg EC Backward Curved Impeller, GKHM 450-CIG.128.6IF IE Gen3+, 5.9kW, 460-Volt, 3-Phase, 6000 CFM @ 4 inWG.

Contact Rosenberg USA for more details.

N88-45700 N88-45700 Rosenberg Backward Curved EC 450 380-480 ~3 60 6300 76

Rosenberg GKHM 450-CII.147.5HF IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 4120 CFM @ 2.44 in WC; 6300 CFM @ free air.

Contact Rosenberg USA for more details.

N88-45701 N88-45701 Rosenberg Backward Curved EC 450 380-480 ~3 60 8829 84

Rosenberg GKHM 450-CII.147.6FF IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5473 CFM @ 4.22 in WC; 8829 CFM @ free air.

Contact Rosenberg USA for more details.

N88-45702 N88-45702 Rosenberg Backward Curved EC 450 380-480 ~3 60 9947 88

Rosenberg GKHM 450-CII.147.6IF IE Gen3+ AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5990 CFM @ 6.11 in WC; 9947 CFM @ free air.

Contact Rosenberg USA for more details.

N88-50317 N88-50317 Rosenberg Backward Curved EC 500 380-480 ~3 60 8534 87

Rosenberg GKHM 500-CIB.160.6IF IE Gen3 AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 4787 CFM @ 4.92 in WC; 8534 CFM @ free air.

Contact Rosenberg USA for more details.

N88-50322 N88-50322 Rosenberg Backward Curved EC 500 380-480 ~3 60 9947 91

Rosenberg GKHM 500-CIB.160.6NA IE Gen3+ AMCA-Certified B-Series backward curved EC fan with seven blade cast aluminum impeller. Airflow 6646 CFM @ 5.73 in WC; 9947 CFM @ free air.

Contact Rosenberg USA for more details.

N88-50322 Gen 3+ N88-50322 Gen 3+ Rosenberg Backward Curved EC 500 230 3 60 6004 93

ROSENBERG EC backward curved impeller, GKHM 500-CIB.160.6NA IE GEN3+, input voltage 200-240 volt (4.2 Kw / 1880 RPM max) and 380-480 volt (7 Kw / 2225 RPM max), 3-phase, 50-60 hz. IP54 and UL-R motor class f with status led indicator, open loop (0-10v, pwm, 4-20 ma, modbus, potentiometer), operating temperature -25°C to +40°C at full speed. module construction with aluminum (ALMG3) high efficiency impeller; front plate (dimensions 700 x 700-mm), motor plate, and inlet cone (with plastic tubing).

ROSENBERG EC backward curved impeller, GKHM 500-CIB.160.6NA IE GEN3+, input voltage 200-240 volt (4.2 Kw / 1880 RPM max) and 380-480 volt (7 Kw / 2225 RPM max), 3-phase, 50-60 hz. IP54 and UL-R motor class f with status led indicator, open loop (0-10v, pwm, 4-20 ma, modbus, potentiometer), operating temperature -25°C to +40°C at full speed. module construction with aluminum (ALMG3) high efficiency impeller; front plate (dimensions 700 x 700-mm), motor plate, and inlet cone (with plastic tubing).

Contact Rosenberg USA for more details.

N88-50322 Gen 3+ N88-50322 Gen 3+ Rosenberg Backward Curved EC 500 460 3 60 8011 98

ROSENBERG EC backward curved impeller, GKHM 500-CIB.160.6NA IE GEN3+, input voltage 200-240 volt (4.2 Kw / 1880 RPM max) and 380-480 volt (7 Kw / 2225 RPM max), 3-phase, 50-60 hz. IP54 and UL-R motor class f with status led indicator, open loop (0-10v, pwm, 4-20 ma, modbus, potentiometer), operating temperature -25°C to +40°C at full speed. module construction with aluminum (ALMG3) high efficiency impeller; front plate (dimensions 700 x 700-mm), motor plate, and inlet cone (with plastic tubing).

ROSENBERG EC backward curved impeller, GKHM 500-CIB.160.6NA IE GEN3+, input voltage 200-240 volt (4.2 Kw / 1880 RPM max) and 380-480 volt (7 Kw / 2225 RPM max), 3-phase, 50-60 hz. IP54 and UL-R motor class f with status led indicator, open loop (0-10v, pwm, 4-20 ma, modbus, potentiometer), operating temperature -25°C to +40°C at full speed. module construction with aluminum (ALMG3) high efficiency impeller; front plate (dimensions 700 x 700-mm), motor plate, and inlet cone (with plastic tubing).

Contact Rosenberg USA for more details.

N88-50604 Gen 3+ N88-50604 Gen 3+ Rosenberg Backward Curved EC 500 230 3 60 4000 87

Rosenberg EC Backward Curved Impeller, GKHM 500-CIG.143.6IF IE Gen3+, 3.47kW, 230-Volt, 3-Phase, 4000 CFM @ 4 inWG

Rosenberg EC Backward Curved Impeller, GKHM 500-CIG.143.6IF IE Gen3+, 3.47kW, 230-Volt, 3-Phase, 4000 CFM @ 4 inWG

Contact Rosenberg USA for more details.

N88-50604 Gen 3+ N88-50604 Gen 3+ Rosenberg Backward Curved EC 500 460 3 60 6000 92

Rosenberg EC Backward Curved Impeller, GKHM 500-CIG.143.6IF IE Gen3+, 5.4kW, 460-Volt, 3-Phase, 6000 CFM @ 4 inWG

Rosenberg EC Backward Curved Impeller, GKHM 500-CIG.143.6IF IE Gen3+, 5.4kW, 460-Volt, 3-Phase, 6000 CFM @ 4 inWG

Contact Rosenberg USA for more details.

N88-50700 N88-50700 Rosenberg Backward Curved EC 500 380-480 ~3 60 10006 85

Rosenberg GKHM 500-CII.164.6IF IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5384 CFM @ 4.76 in WC; 10006 CFM @ free air.

Contact Rosenberg USA for more details.

N88-50701 N88-50701 Rosenberg Backward Curved EC 500 380-480 ~3 60 11772 89

Rosenberg GKHM 500-CII.164.6NA IE Gen3+ AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 6949 CFM @ 6.03 in WC; 11772 CFM @ free air.

Contact Rosenberg USA for more details.

N88-50702 N88-50702 Rosenberg Backward Curved EC 500 380-480 ~3 60 6769 76

Rosenberg GKHM 500-CII.164.5HF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 4231 CFM @ 2.00 in WC; 6769 CFM @ free air.

Contact Rosenberg USA for more details.

N88-50703 N88-50703 Rosenberg Backward Curved EC 500 380-480 ~3 60 9417 84

Rosenberg GKHM 500-CII.164.6FF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 5696 CFM @ 3.80 in WC; 9417 CFM @ free air.

Contact Rosenberg USA for more details.

N88-56601 N88-56601 Rosenberg Backward Curved EC 560 460 3 60 7328 92

ROSENBERG GKHM 560-CEG.160.6NA IE, input voltage 380-480 volt (5.1 kw max), 3-phase, 50-60 Hz. IP54 and UL-R motor class f, operating temperature -20°c to +40°c, very high efficiency impeller with 6 blades painted quart grey (RAL 7039), galvanized steel inlet cone with pressure measuring tabs & tubing (k factor 234). soft start and maximum rotation speed 1950 RPM. total weight 74 Kg.

ROSENBERG GKHM 560-CEG.160.6NA IE, input voltage 380-480 volt (5.1 kw max), 3-phase, 50-60 Hz. IP54 and UL-R motor class f, operating temperature -20°c to +40°c, very high efficiency impeller with 6 blades painted quart grey (RAL 7039), galvanized steel inlet cone with pressure measuring tabs & tubing (k factor 234). soft start and maximum rotation speed 1950 RPM. total weight 74 Kg.

Contact Rosenberg USA for more details.

N88-56604 Gen 3+ N88-56604 Gen 3+ Rosenberg Backward Curved EC 560 460 3 60 8000 94

Rosenberg EC Backward Curved Impeller, GKHM 560-CIG.160.6NA IE Gen3+, 6.85kW, 460-Volt, 3-Phase 8000 CFM @ 4 inWG.

Rosenberg EC Backward Curved Impeller, GKHM 560-CIG.160.6NA IE Gen3+, 6.85kW, 460-Volt, 3-Phase 8000 CFM @ 4 inWG.

Contact Rosenberg USA for more details.

N88-56604 Gen3+ N88-56604 Gen3+ Rosenberg Backward Curved EC 560 230 3 60 6000 88

ROSENBERG GKHM 560-CIG.160.6NA IE, GEN 3+, INPUT VOLTAGE 230+460 VOLT, 50/60 HZ, 3 PH

ROSENBERG GKHM 560-CIG.160.6NA IE, GEN 3+, INPUT VOLTAGE 230+460 VOLT, 50/60 HZ, 3 PH

Contact Rosenberg USA for more details.

N88-56700 N88-56700 Rosenberg Backward Curved EC 560 380-480 ~3 60 12831 84

Rosenberg GKHM 560-CII.183.6NA IE Gen3+ AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 8003 CFM @ 4.47 in WC; 12831 CFM @ free air.

Contact Rosenberg USA for more details.

N88-56702 N88-56702 Rosenberg Backward Curved EC 560 380-480 ~3 60 9947 77

Rosenberg GKHM 560-CII.183.6FF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 8003 CFM @ 4.47 in WC; 12831 CFM @ free air.

Contact Rosenberg USA for more details.

N88-56703 N88-56703 Rosenberg Backward Curved EC 560 380-480 ~3 60 11301 81

Rosenberg GKHM 560-CII.183.6IF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 6765 CFM @ 3.71 in WC; 11301 CFM @ free air.

Contact Rosenberg USA for more details.

N88-63601 Gen 3+ N88-63601 Gen 3+ Rosenberg Backward Curved EC 630 230 3 60 6000 84

Rosenberg EC Backward Curved Impeller, GKHM 630-CIG.180.6NA IE Gen3+, 3.59kW, 230-Volt, 3-Phase, 6000 CFM @ 3 inWG

Rosenberg EC Backward Curved Impeller, GKHM 630-CIG.180.6NA IE Gen3+, 3.59kW, 230-Volt, 3-Phase, 6000 CFM @ 3 inWG

Contact Rosenberg USA for more details.

N88-63601 Gen 3+ N88-63601 Gen 3+ Rosenberg Backward Curved EC 630 460 3 60 10000 83

Rosenberg EC Backward Curved Impeller, GKHM 630-CIG.180.6NA IE Gen 3+, 5.1kW, 460-Volt, 3-Phase, 100000 CFM @ 2 inWG

Rosenberg EC Backward Curved Impeller, GKHM 630-CIG.180.6NA IE Gen 3+, 5.1kW, 460-Volt, 3-Phase, 100000 CFM @ 2 inWG

Contact Rosenberg USA for more details.

N88-63700 N88-63700 Rosenberg Backward Curved EC 630 380-480 ~3 60 12831 80

Rosenberg GKHM 630-CII.200.6NA IE Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 7696 CFM @ 3.26 in WC; 12831 CFM @ free air.

Contact Rosenberg USA for more details.

N88-63701 N88-63701 Rosenberg Backward Curved EC 630 380-480 ~3 60 11772 79

Rosenberg GKHM 630-CII.200.6IF Gen3 AMCA-Certified backward curved I-Series EC fan with five-blade sheet aluminum impeller. Airflow 6615 CFM @ 2.99 in WC; 11772 CFM @ free air.

Contact Rosenberg USA for more details.

P02-A4 P02-A4 Ecofit Backward Curved AC 250 230 1 60 1200

P02-A4 – EVOFIT 2RREU45 250X50R; 230-volt, 1-phase, 60 Hz. AC backward curved motorized impeller, includes: IP44 & UL-R motor class F motor, operating temperature -40° TO +55° celsius, 900-mm connection cable on the rear side of the motor; 250-mm diameter high efficiency galvanized steel impeller. Height C = 108-MM

Contact Rosenberg USA for more details.

Q08-A8 Rev. b Q08-A8 Rev. b Ecofit Backward Curved AC 250 115 1 60 990

Ecofit 2RREu45 250X50R, 115V, 1-phase, 50-60 Hz, IP44 & UL-R motor, high efficiency metal impeller, ERP 2015

Ecofit 2RREu45 250X50R, 115V, 1-phase, 50-60 Hz, IP44 & UL-R motor, high efficiency metal impeller, ERP 2015

Contact Rosenberg USA for more details.

Q13-A0 Q13-A0 Ecofit Backward Curved AC 250 230 1 60 1038 71

Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.

Q13-A0, 2RREu45 250x50R, E-Impeller, 1-phase, 230-Volt, 220 Watts, Max airflow at free air 1038 CFM, temperature range -40 to +70°C. ERP 2015 compliant.

Contact Rosenberg USA for more details.